VDS-BUS2 Programming
VDS-BUS2 Programming
To programme the lock-release time from the exit button, while in time pro-
gramming mode, (having fi nished programming the lock-release time from the
residence or following the indicator tones), wait 5 seconds before taking any
other action.
5.- At this time a new confi rmation tone will sound indicating the change to en-
trance hall lock-release programming mode, then subsequently emitting the
aforementioned beeps detailing the time programmed.
6.- Once the current time indicator tones have concluded, or before they conclude,
press any button on the panel, with one press for each second to be programmed
(from 1 to 99 seconds).
To exit programming mode, wait 5 seconds without pressing any key. A "MUOK"
sound will be emitted indicating that you have exited time programming mode.
If you enter time programming mode and do not press any key, this mode will
automatically be exited after 30 seconds.
KEYPAD Programming
You can also programme lock-release times using a BUS2 Direct auxiliary keypad.
For more information refer to the "BUS2 Direct Panels - Lock-Release Program-
ming" section of the BUS2 technical manual; code 97462 available at www.
fermax.com.
The connection for the BUS 2 Direct keypad and the BUS2 amplifi er is detailed un-
der Section II of the BUS2 Technical Manual under "Bus2 Direct Panel Prewiring".