Qlima S95 Instrucciones De Uso página 99

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
If the air conditioner is operating in the COOLING or DRY mode and a door or window is open for some
time while the relative humidity is more than 80%, moisture may drip out of the air outlet of the indoor
unit.
Noise
-
Install the air conditioner on a solid base in order to prevent excessive noise.
-
Install the outdoor unit in such a way that the expelled air does not cause a nuisance for neighbours.
-
Do not place obstacles in the path of the air expelled from the outdoor unit, this increases noise.
Safety features
1
The safety feature deactivates the unit in the following cases:
- When the function is stopped or changed while the unit is operating. Wait 3 minutes before
switching the air conditioner on again.
- After the plug has been inserted in the socket and the unit has been immediately switched on. The
unit will activate after approximately 20 seconds.
2.
Press the ON/OFF button to restart after the unit has deactivated due to the operation of the safety
feature. The Timer must then be reset.
Checks
The following must be checked after the air conditioner has been in use for an extended period of time:
-
Overheating of the power cable and the plug. Can you smell burning?
-
Is there more noise or vibration than normal?
-
Does the indoor unit leak water?
-
Is the metal housing live?
Switch the air conditioner off in all the above cases! We recommend that inspection for the above be
conducted after 5 years in operation, even if no faults have occurred.
Feature of the HEATING mode
For heating
When the HEATING function is activated, the airstream will only start to flow from the indoor unit after
2 – 5 minutes.
After Heating
When the Heating function is deactivated, the ventilator of the indoor unit will continue operating for
another 2 – 5 minutes.
Defrosting
During HEATING, the machine will defrost automatically in order to ensure optimum operating efficiency.
This procedure usually takes 2-10 minutes. The ventilator function stops during defrosting. The HEATING
function restarts automatically after defrosting.