Pcb; Description Of Pcb Inputs/Outputs; Pcb Diagram - AERMEC SWP200 Manual De Usuario

Pompe di calore acqua calda sanitaria
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

10.

PCB

10.1.
DESCRIPTION OF PCB INPUTS/
OUTPUTS
DIGITAL INPUTS:
HP= high pressure
BP= low pressure
(ID3)= ANALOGUE INPUT provision
only:
S1= water probe
S2= air probe
(S3= input provision only)
RELAY OUTPUTS:
NR,FR=
heating element activation
consent
NV,FC= fan activation consent
NC,FC= compressor activation
consent (and, in parallel,
any servocontrol for D160S
distributor)
48
SWP_5287500_00
10.2.

PCB DIAGRAM

water probe
internal air probe
optional air probe
heating element
power supply
(any servocontrol for D160S)
compressor
fan