Side broom replacement

WARNING!
It is advisable to wear protective gloves when replacing the side broom because there can be sharp debris
between the bristles.
1.
Lift the hopper until the side broom is approximately at chest height.
2.
Release the spring to remove the mounting pin (A, Fig. 6) and remove the side broom (B) from the motor shaft.
3.
Install the new broom on the motor shaft, align the hole with the mounting pin and engage the mounting pin (A).
A
Figure 6
Proterra™
INSTRUCTION FOR USE
B
33019867(2)2010-09