Troubleshooting

Fault
The appliance is
The unit is not switched on
not working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Appliance does
Open end of bag not completely
not remove all
inserted
the air from the
Gaskets dirty
bag
Open end of bag is dirty
Bag may be punctured
Incorrect bags used
Suction nozzle blocked
Lid is not locked into position
correctly
Bags are not
Moisture in bag under the sealing
sealing correctly
bar
Incorrect bags used
End of bag not placed above sealing
bar

Technical Specifications

Model
Voltage
CN514
220-240V
50Hz
CN514_ML_A5_v6_20190513.indb 7
Probable Cause
Vacuum Pressure
Power
Current
(approx.)
130W
0.6A
Solution
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified Technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Open lid and reposition bag
Clean gaskets
Clean bag
Replace bag
Call Vacuum Pack machine supplier
Clear suction nozzle
Ensure lid is locked in position correctly
Ensure inside of the bag is dry and free from
moisture where it is to be sealed
Call Vacuum Pack machine supplier
Move end of bag over sealing bar
Dimensions
h x w x d mm
-0.90Bar
125 x 400 x 265
UK
Weight
(kg)
3.5
7
2019/5/13 17:45