Information On The Electrical Connections - Dometic GROUP WAECO PerfectView CAM80 Instrucciones De Montaje

Cámara de vídeo de marcha atrá
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
_CAM80.book Seite 28 Freitag, 20. Mai 2011 3:18 15

Information on the electrical connections

7
Information on the
electrical connections
7.1
Laying cables
A
NOTICE! Risk of damage!
 To prevent damage, when drilling ensure that there is sufficient
space on the other side for the drill head to come out.
 Cables and connections which are not properly installed will
cause malfunctions or damage to components. Correct installa-
tion of cables and connections is the basic prerequisite for last-
ing and trouble-free operation of the retrofitted components.
 The cables may not be exposed for long periods to solvents
such as benzine, as the solvents can damage the cable.
Please observe the following instructions:
 As far as possible, use original openings or alternative openings for the
connecting cable duct, e.g. the paneling edges, ventilation grilles or blank
panels. If no openings are available, you must drill holes for the cables.
Check beforehand that there is sufficient room for the drill head to come
out on the other side.
 Wherever possible lay cables inside the vehicle, as they are better
protected inside than outside the vehicle.
If you do need to lay a cable outside the vehicle, ensure that it is well
secured (use additional cable ties, insulating tape, etc.).
 To prevent damage to the cables, when laying them ensure that there is
sufficient distance to hot or moving vehicle components (exhaust pipes,
drive shafts, light systems, fans, heater etc.). Use corrugated piping or
other protective materials to protect against mechanical wear.
 Verschrauben Sie die Steckverbindungen der Verbindungskabel zum
Schutz gegen das Eindringen von Wasser (fig. g, page 6).
 When laying electric connections, ensure that
– They are not kinked or twisted
– They do not rub on edges
– They are not laid in sharp edged ducts without protection (fig. 3,
page 3)
 Attach the cables securely in the vehicles to prevent tripping hazards.
Use cable binders, insulating tape or glue the cables in place.
28
PerfectView CAM80
Tabla de contenido
loading

Tabla de contenido