Thank you for purchasing a TAKEX product. This sensor will provide long and dependable service when properly installed. Please read this Instruction
Manual carefully for correct and effective use.
Please Note : This switch is designed to detect passing objects and to initiate a signal ; it is not a burglary-preventing device.
TAKEX is not responsible for damage or losses caused by accident, theft, Acts of God (including lightning), abuse, misuse, abnormal
usage, faulty installation or improper maintenance.
PRODUCT DESCRIPTION :
This sensor unit uses a passive infrared sensors to detect infrared (≒ body temprature) emitted from a human body, which can be used as automatic
switch. This unit is designed for wide applications such as a switch to control illumination or home automation.
TROUBLESHOOTING :
Symptom
Inactive
Malfunction
False Signal
Installed unit does not
operate, while LED is on
If normal operation cannot be restored by these means, contact either the dealer from whom you bought the unit or TAKEX directly.
SPECIFICATIONS :
Sensor Switch
Model
Detection system
Coverage
Supply voltage
Current consumption
Alarm output
Tamper output
Sensitivity adjustment
Ambient temperature
Mounting position
Operation LED
Connection
Weight
Appearance
Optional
※Specifications and design are subject to change without prior notice.
Limited Warranty :
TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover
damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided
by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in duration to
12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts returned
prepaid. Please provide the model number of the products, original date of shipment and nature of diffculty being experienced. There will be charges rendered for
product repairs made after our Warranty Period has expired.
MAINTENANCE
・To clean the device, use a soft, wet cloth and then wipe off any water drops. If the device is particularly dirty, dip the soft cloth in the water that contains a weak
neutral detergent. Wipe the device gently with the cloth, then wipe off any detergent that remains.
Do not use substances such as thinner or benzene. (The plastic parts may deform, discolor or change their properties.)
・Perform operation checks on a regular basis.
Instruction Manual MS-100E
Analyze possible problems according to the following table.
Possible Cause
1. No power supply. Inadequate voltage.
2. Warm-up period.
3. Obstructions in the coverage.
4. Incorrect adjustment of coverage.
5. Stained cover.
1. Unstable voltage.
2. Something moving or rapid temperature variation in
detection area.
3. A large electric noise source is located nearby.
4. Direct sunlight shining on the unit.
5. Detecting untargeted objects.
6. Small animals.
1. Bad wiring connection or broken wire or short circuit.
2. Improper terminal connection.
3. Improper unit is connected.
MS-100E
Passive infrared
Vertical Installation
・Wide Angle [Max. 10m (33')]
・Curtain
[Max. 10m (33')]
・Long Range [Max. 20m (66')]
Horizontal Installation
・Vertical Curtain [Max. 3m (10')]
10.5VDC to 28VDC (Non polarity)
30mA MAX.
Dry contact relay output Form N.C. / N.O. selectable
・Contact capacity : 30V (AC ・ DC), 0.5A MAX.
(Resistive load)
・Contact operation : Detection time + delay time
(Approx. 2 sec.)
Dry contact relay output N / C
・Contact capacity : 30V (AC ・ DC), 2A MAX.
(Resistive load)
・Approx. 30% ( L ) --- Approx. 170% ( H )
(100% : set at factory)
-4° F to +122° F (-20° C to +50° C)
Vertical Installation
・Indoor / outdoor (height : 0.8 - 1.5m)
Horizontal Installation
・Indoor (height : 3m MAX.)
Lighting at alarm
Terminals
7.7 oz (220g)
Cover : PE resin (white) Body : AES resin (White)
Wall mount attachment (BW-14), Pole attachment (BP-12)
Pole cover (BP-11), Magnetic sheet (BR-M5)
1. Ensure correct and adequate supply voltage.
2. Wait 1 min. after power is supplied.
3. Remove obstructions.
4. Readjust the coverage.
5. Clean with soft cloth.
1. Stabilize supply voltage.
2. Remove cause or change coverage.
Turn the sensitivity adjustment down.
3. Remove the problem or replace the unit.
4. Remove the problem or replace the unit.
Readjust the coverage.
Insert the attached filter.
5. Readjust the coverage.
6. Prevent small animals from coming in or readjust the unit.
1. Check wiring again.
2. Check terminal connection with a tester.
3. Check connected unit.
⑤
Remedy