Full Code Reset (A9)
This operation allows deletion of all existing access codes in the system's memory.

Restoring Factory Settings

Resetting the Master or Free Access/Trade Code (where you have forgotten
the previous one)
This operation is carried out by electrically modifying the equipment, in the aim of ensuring
it is impossible for anyone without physical access to the equipment to modify it in any way.
1. Disconnect the system's power supply.
2. Short-circuit the "S2" and the system.
If the system is equipped with a PI exit button, just press and hold it down (refer to
the installation diagram).
3. Reconnect the system's power supply and remove the short-circuit (or release the
exit button) within 5 seconds.
4. If the process has been carried out correctly a double "beep" will sound and the
green light will stay on. Next enter the following code A708B9. A double "beep" will
sound and the system will reset itself, restoring its factory settings.
NOTE: The restoration of default factory settings does not delete the rest of the information programmed on
the system.
Default Free Access (trade) Code :
- 4 digit length: 1593
- 5 digit length: 15935
- 6 digit length: 159357
If for any reason we need to reset any of these codes, having forgotten the previous one
(refer to the corresponding chapter: "Restoring Factory Settings"), these are the codes
that will be set on undertaking the operation in line with the code length established on the
system.
1 Enter programming mode:
2 Enter the relevant option:
3 Re-enter the master code (set by
default as 1480) to confirm all codes
have been deleted.
Example:
Reset all existing access
codes.
NOTE: Resetting is an irreversible operation, whereby any previously stored codes
cannot be recovered.
Master Code (1480)
A9
1480
1480 A9 1480
beep (x3)
beep (x3)
beep (x3)