Restricted Applications - Falltech 7262 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Be sure to consult Section 5 of this instruction manual for details on
anchorage considerations, as the anchorage and its relationship to the
walking/working surface will be an important factor in determining
suitability and could contribute to the outcome of a fall event. Use of an
anchor point that is not properly rated could lead to a catastrophic failure
of your personal fall arrest system, which may result in serious injury or
death.
Direct Overhead Applications: This product is suitable for use in any
application where the properly rated anchorage is directly above the
walking/working surface, and allows for a maximum Free-Fall Distance of
2 feet.
Horizontal Lifelines: This product is suitable for use in any application
where a horizontal lifeline has been installed under the guidance of a
qualified person, and where the Free-Fall Distance does not exceed 2
feet.
Residential Construction: This product is suitable for use in residential
construction applications provided the anchorage meets the basic
requirements outlined in Section 5 of this instruction manual.
General Construction: This product is suitable for use in general
construction applications provided the anchorage meets the basic
requirements outlined in Section 5 of this instruction manual, Free-Fall
does not exceed 2 feet, and there is no exposure to a sharp leading
edge.
Climbing/Fixed Ladders: This product is suitable for use on fixed ladders
or in conjunction with fixed ladder equipment, provided that the
anchorage meets the basic requirements outlined in Section 5 of this
instruction manual and provided that it is used in conjunction with a Full
Body Harness (FBH) containing a front or chest d-ring. Free-Fall must
not exceed 2 feet.
General Industrial Use: This product is suitable for use in general
industrial applications provided the anchorage meets the basic
requirements of Section 5 of this manual and provided that it is not
exposed to sharp edges, electrical hazards or prolonged exposure to
highly corrosive environments or substances.
Industrial Lift Trucks: This product is suitable for use in industrial lift
trucks and order pickers.
15
If you have any questions regarding the suitability of this product for
your specific application, please consult with a competent person or
contact FallTech before using. Misuse of this product may result in
serious injury or death.

3.3: Restricted Applications

Leading-Edge Work: This product is not suitable for leading-edge work
except in the case of residential roofing applications.
Offshore Oil Rigs: This product is not suitable for offshore drilling
applications where there will be prolonged exposure to the corrosive
exposure to sea air and/or salt water.
Harsh Chemical Environments: Acids and other caustic chemicals can
cause damage to this SRL and its components. Damage from chemical
exposure can be difficult to detect and FallTech recommends frequent
replacement and/or factory service.
Arborist Applications: This product should never be used in arborist
applications or tree-trimming applications.
Aerial Lifts: This product is not approved for use in aerial lifts, bucket
trucks or scissor lifts.
Extended Free-Falls: This product should not be used in applications
where free-fall exceeds 2' (2 feet).
Heavyweight: This product should not be used in applications where the
total weight of the user (including clothing, tools and equipment) exceeds
310 lbs.
Power Transmission: Use of this product in areas where the lifeline may
come in contact with electrical hazards is prohibited (with the exception
of model # 7270KV). FallTech recommends the use of Aramid webbing
SRL's (Kevlar®, Nomex® or Dyneema®) for these applications.
Welding: Use of this product in areas where the lifeline may come in
contact with high heat or welding slag is not recommended. FallTech
recommends the use of Aramid webbing SRL's (Kevlar®, Nomex® or
Dyneema®) for these applications.
Residential Roofing: This product is not suitable for use in residential
roofing applications.
16