Setting
[display]
MENU 3. CALIBRATION SETTINGS WEIGHING INDICATOR
DISPLAY UNIT
[lb-kg]
MENU 4. PRESET, RECIPE & COUNTER FUNCTIONS
PREALARM
[P MTHD] & [P-ALM]
SIREN
[BUZZER]
TIMER/COUNTER
[TMRCTR]
DRIVE RATIO
[DRATIO]
TOLERANCE
[TOLER]
INGR. ADVANCEDELAY
[DELAY]
USER ID
[USERID]
RESIZING RECIPE.
[RESIZE]
RECIPE TOTAL
[RECTOT]
TOLERANCE OVERLOCK
[OVERLK]
FEED ZONE
[FDZONE]
D3715-ESP Rev E
Hacer listado con números de acceso directo
Options [displayed]
Access
Nº
(bold=default)
303
LB/KG
WEIGHT
401
PERCNT
404
1-4, ON/OFF
REV.
421
TIME
422
0001.00
442
OFF, 5,1-5,7,10
MANUAL, 1-3,5,7,
443
10,20,30,60
446
ON/OFF
448
ON/OFF
451
ON/OFF
453
ON/OFF
454
ALL, 1-9
EZ3600 Manual del Usuario
Description
Display in lb or kg.
Select WEIGHT or PERCNT and
enter a value to activate an early
warning indicating that the weighing
indicator is reaching the preset
amount.
Switching the loud alarm signal ON
or OFF.
Determination of the recipe mixing
time based on time or on the
number of mixing auger revolutions.
The number of input impulses (PTO
revolutions), which correspond with
one single revolution of the mixing
auger.
The tolerance (percentage of the
ingredient amount) to accept the
ingredient.
The number of seconds the
weighing indicator should wait
before automatically advancing to
the next ingredient.
If this setting is ON, the operator
should enter the user ID to use the
weighing indicator.
If this setting is ON, the operator can
adjust the recipe amount.
Displayed total weight of the recipe
to be loaded.
If this setting is ON, the weighing
indicator does not automatically
advance to the next ingredient when
exceeding the set tolerance.
The feed zone of the groups to be
fed.
32