Astralpool 41005 Manual De Instrucciones página 29

Armario de maniobras
Idiomas disponibles

Idiomas disponibles

6.6.- PNEUMATIC MOTORIZED VALVES CONNECTION.
Connect the lead's terms to the valve connector according to the picture. The nº2 Lead
is not used.
Make a bridge with lead nº5 (common) and nº 1 on the limit switch
Repeat the same process with the other valves, having connected them previously in
strict order (connector nº 1 to valve nº 1, nº2 to nº2, and so on.)
There is no valve nº5 in the 4-valve batteries.
Fig .12.- Pneumatic motorized valves connection.
INSTALLATION AND
OPERATION MANUAL
Rev:
03
Year:
2011
Page:
12 / 17
ENG
loading

Este manual también es adecuado para:

41012