8.
Installation of Fitting for In-wall Installation (1-part Function Block)
8.1
Remove the cover plate.
☞
For further details please consult the Installation and Operating Instructions for the
fitting.
8.2
Use a hollow hexagon wrench to close the water volume regulators.
a: closed
b: open
8.3
Trigger the valve.
Spare parts
8.4
Disconnect the line connection between the solenoid valve cartridge and the
electronic module.
8.5
Remove the screws (c).
8.6
Remove the solenoid-valve cartridge (d).
8.7
Use a flat nose pliers to pull the existing filter (e) out.
8.8
Continue with
Retrofitting thermal disinfection
8.9
Remove the screws (f).
8.10 Unscrew the plug (g).
☞
Use an M8 screw to pull out the plug via the centre thread.
8.11 Insert the new filter.
☞
Important!
Ensure correct installation position. The rib of the filter must not lie on the flow-
through hole.
8.12 Insert the solenoid-valve cartridge.
8.13 Tighten the screws.
8.14 Connect the line connection between the solenoid-valve cartridge and the electronic
module (k).
l: Solenoid-valve cartridge mixed water
m: Solenoid-valve cartridge bypass, thermal disinfection
☞
Insert an adapter (n) if necessary.
8.15 Mount the cover plate.