Milwaukee 4270-20 Manual Del Operador página 4

Prensa taladradora electromagnetica compacta
Ocultar thumbs Ver también para 4270-20:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1.
Always use safety strap when drilling overhead or on a vertical surface (see "Safety Strap" under "Operation"). Mounting can release.
2.
Clean the surface before attaching the drill stand to the work surface. Paint, rust, scale, or uneven surfaces decrease the holding strength of the
magnet. Chips, burrs, dirt and other foreign matter on the surface of the magnet base will also decrease holding power.
3.
Do not attach magnetic base to nonmagnetic grades of stainless steel. The magnetic base WILL NOT hold. The electromagnetic drill press at-
taches magnetically to 3/8" or thicker ferrous stock. Do not use on stock less than 3/8".
4.
Wet connections are shock hazards. If the plug or connections get wet, turn power off to the outlet before unplugging the tool. Prevent cutting fl uid
from traveling along the cord and contacting the outlet, extension cord connections or tool plug. Each time tool is plugged in, elevate extension cord
or gang box connections and arrange a drip loop.
5.
Maintain labels and nameplates. These carry important information. If unreadable or missing, contact a MILWAUKEE service facility for a free re-
placement.
6.
Wear ear protectors with impact drills. Exposure to noise can cause hearing loss.
7.
Hold power tools by insulated gripping surfaces when performing an operation where the cutting tool may contact hidden wiring or its own
cord. Contact with a "live" wire will make exposed metal parts of the tool "live" and shock the operator.
8.
WARNING! Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer,
birth defects or other reproductive harm. Some examples of these chemicals are:
lead from lead-based paint
crystalline silica from bricks and cement and other masonry products, and
arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to fi lter out microscopic particles.
9.
Safety Strap
A.
Do not use near acids or bleaching agents.
B.
Do not use for overhead lifting.
C.
Do not use strap if webbing is cut.
D.
Webbing must be protected from sharp edges.
E.
All hardware must be in line with direction of pull for rated capacity.
page 4
SPECIFIC SAFETY RULES FOR ELECTROMAGNETIC DRILL PRESS
Volts Alternating Current
Amps
Double Insulated
No Load Revolutions per Minute (RPM)
Underwriters Laboratories, Inc.
Canadian Standards Association
DANGER! To reduce the risk of injury, always keep hands, rags,
clothing, etc. away from moving parts and chips. Do not try to
remove chips while the cutter is rotating. Chips are sharp and
can pull objects into moving parts.
Volts
AC
Cat.
Only
No.
Amps
120
4270-20
9.0
* Requires use of 1/2" drill chuck adapter, see "Accessories."
Symbology
Specifi cations
Arbor
No Load
Bore
RPM
3/4"
450
HSS
*Twist
Drill
Cutter
1/2"
1-1/2"
Tabla de contenido
loading

Tabla de contenido