E & DL Series - Filters
Regular maintenance of the filtration system is
recommended to ensure maximum performance of
your central vacuum. For models of the DL series,
the Information Center will indicate when to empty
the canister and clean the filters. These indications
are provided by an electronic timing board, only as
a reference guide.
Your central vacuum is equipped with two filters.
The anti-clogging filter (thin fabric) stops the
larger particles, and the Cyclofiltre (thick fabric)
catches the microscopic particles. The Cyclofiltre
is equipped with an antimicrobial treatment to
prevent the growth of mold, fungus and bacteria.
This filter is washable in cold water (no bleach)
and can be dried at low temperature.
1. To remove the filters, first remove the dust
receptacle (figure 11).
2. Then, use the straps at the base of the filters
to withdraw (figure 12) We recommend cleaning
the anti-clogging filter (thin fabric) every time
the dust receptacle is emptied. You may either
shake it out, or rinse it. The Cyclofiltre (thick
fabric) should be cleaned after four anticlogging
filter cleanings, or approximately once a year.
3. Both filters must be completely dry before they
are reinstalled. Carefully install them in the
support grooves (figure 13) on the filter frame
to ensure adequate protection of the motor.
Install the Cyclofiltre (thick fabric) first, and the
anticlogging filter (thin fabric) over.
Inspect the filters for tears and punctures before
reinstalling them. Do not reinstall damaged filters.
22
support
grooves
Maintenance
figure 11
figure 12
figure 13