7.3___SAVING THE PARAMETERS
To save the parameters set in the programming menu,
press the
key, holding it down for 5 seconds and
waiting for the SAVE PAR message.
7.4___CURRENT-PROPORTIONAL CONTROL
It is possible to set current-proportional control by means of the following variables:
PHS
PHE
RDS
RDE
In order to control the metering, it is necessary to have a pump with a current input of 0-20 mA or
4-20 mA.
The current output can also be used to connect a paper-type recorder.
7.5___SET-POINT FUNCTION
Using the
key, this function enables the user
to view the SET POINTs cyclically. They can be
changed by means of the
without having to enter the programming mode.
If protection was implemented on the terminal strip
and the SET step was programmed as OFF, the
Key can only be used to view the SET
POINTs, without it being possible to change them.
7.6___MANUAL CONTROL AND PRIMING OF
THE PUMPS.
If the
is held down, it is possible to activate the control relays of the pH and Redox (chlorine)
pump in sequence by pressing the
This function is useful for priming the pumps.
Warning: If the pump is current-controlled, it is necessary to configure it manually before forcing it
to start up via the keypad.
7.7___FLOW ALARM
A flow sensor positioned in the piezometric overflow device of the POOL TOP equipment is
connected to terminals 13 and 14. If the flow rate of the water drops so much that the
measurements are prejudiced, this sensor will stop the chlorination and generate an alarm signal.
pH 0
pH 14,00
0 mV
999 mV
and
keys
key.
.
Initial value for mA control
Final value for mA control
Initial value for mA control
Final value for mA control