7
Filling
Before use, remove the tank cap and fill the tank through the
filter with the chosen liquid substances, then reposition the cap.
Attention: Check that the drain plug and the main filter are
closed. Never immerse the pump in water to clean it or fill it!
Turning on and off
To switch the electric pump on / off, press the red button next to the charging
port and the voltmeter.
Pressure regulator
With the pressure regulator, it is possible to vary the vaporization
size and increase the spraying power depending on the nozzles
and the substances used. The pressure can be regulated from
1 to 10 bar. Turn the adjusting knob clockwise to increase the
pressure. Turn the adjusting knob counterclockwise to decrease
the pressure.
Pressure indicator
The pressure gauge shows at what pressure the pump is
operating. It indicates the pressure generated and the operating
pressure of the pump.
100
Art. 303 / Art. 304
Wheelbarrow battery pump 80 L and 100 L
Usage
Art. 303 / Art. 304
Wheelbarrow battery pump 80 L and 100 L
Usage
Engine's automatic Start&Stop
With the pump switched on: to ensure an optimal use of the battery, the engine only starts by holding
the switch handle. The engine turns off when the switch handle is released.
The start & stop system only works with battery charge above 50%.
Fill indicator
Through the transparent tube positioned between the engine and the tank it
is possible to check the quantity of liquid in the tank. The red ball indicates
the filling level.
Control of the switch handle
The pump is equipped with a hook that allows locking the handle in order to facilitate the work
of the user. It is possible to obtain a continuous spraying, without holding down the handle all
the time, thanks to the special hook.
1. Closed - 2. Continuous
Jet regulation
To change the type of jet it is possible to turn the rear part of the
nozzle. By screwing and unscrewing the rear part of the nozzle, it
is possible to set the jet form pulverization to traditional jet.
7
1
2
101