7.3 Heating operation logic
Working
Working mode
status
1
2
When you
select the
3
"Smart
working mode "
4
5
Start-up
When you
of
6
select
heat
the "Silent
pump
7
working mode".
8
When you
select
the "Powerful
9
working mode."
10
When HP is
11
working at "
12
Smart mode"
Re-start
13
to
14
When HP is
heat
15
working at "
water in
16
Silent mode"
standby
When HP is
status
working at "
17
Powerful
mode"
7.
7.
7.
Start-up
Start-up
Start-up
of
of
of
the
the
the
Water in
temperature-T1
T1< Tset-1
Tset-1≦T1 < Tset
Tset≦ T1 <Tset+ 1
T1≧Tset+1
T1< Tset
Tset≦T1 < Tset+1
T1≧Tset+1
T1<Tset+1
T1≧ Tset+1
T1≧Tset
Tset>T1≧Tset-1
Tset-1>T1≧Tset-2
<Tset-2
≧Tset
Tset>T1≧Tset-1
T1<Tset-1
T1<Tset-1
- 39 -
Heat
Heat
Heat
Pump
Pump
Pump
For example ,
water in
temperature-T1
Powerful mode-frequency F9
T1< 27℃
27℃≦T1 <28℃
Frequency:F9 -F8-F7,...,-F2
28℃≦ T1 <29℃
Silent mode-frequency F2
HP will be in Standby, stop
T1≧29℃
working until the water
temperature drops to less 28℃.
T1< 28℃
Smart mode -frequency F5.
28℃≦T1 < 29℃
Silent mode-frequency F2/F1.
HP will be in Standby, stop
T1≧29℃
working until the water
temperature drops to less 28℃.
Powerful mode-frequency
T1<29℃
F10/F9
HP will be in Standby, stop
T1≧29℃
working until the water
temperature drops to less 28℃.
Standby
T1≧28℃
28℃>T1≧27℃
Silent-frequency F2
27℃>T1≧26℃
Frequency: F2 -F3-F4,...,-F9
<26℃
Powerful-frequency F9
Standby
≧28℃
28℃>T1≧27℃
Silent mode-frequency F2/F1
Smart -frequency F5
T1<27℃
Powerful -frequency F10/F9
T1<27℃
Heat pump working level