Ignition Switch - MAG MG3000 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3 Startup in electrical mode with battery.
Only models with electrical startup MAG6200E, for models without electrical
startup MAG3000 and MG5500 continue to point 4.
Press the engine's ignition switch to "ON" and then to "START", release once
the engine has started.
NOTE: IF the engine does not start up within 3 or 4 seconds, release the
ignition switch and wait for a few seconds before trying again to avoid
overheating the ignition switch.

IGNITION SWITCH

Once started wait for a few seconds and then turn the choke lever to the right
"RUN" (open air position). The engine will begin working stably and is ready to
have equipments plugged in.
CHOKE
.
NOTE: Do not leave the choke in an intermediate position, the blend would
be too rich and the engine would not work properly.
During the first commissioning of the machine the battery's charge may be low if
stored for too long.
manually (go to point 4).
generator is running.
If the charge is not sufficient, start up the equipment
The battery is recharged automatically while the
12