Brush Information; Machine Setup; Installing Brush - Tennant T1 Manual Del Operario

Ocultar thumbs Ver también para T1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

OPERATION
EN

BRUSH INFORMATION

Soft Nylon Bristle Scrub Brush -
Part No. 1037197 (standard)
Recommended for cleaning coated floors without
removing finish. Cleans without scuffing.
Polypropylene Bristle Scrub Brush -
Part No. 1037277 (option)
This general purpose polypropylene bristle scrub brush
is used for scrubbing lightly compacted soilage. This
brush works well for maintaining concrete, wood and
grouted tile floors.
Abrasive Bristle Scrub Brush -
Part No. 1037278 (option)
Nylon fiber impregnated with abrasive grit to remove
stains and soilage. Strong action on any surface.
Performs well on buildup, grease, or tire marks.

MACHINE SETUP

INSTALLING BRUSH

FOR SAFETY: Before installing brush, turn off
machine and unplug power cord from wall outlet.
1. Raise the scrub head to the transport position by
stepping on the scrub head lift pedal (Figure 1).
6
FIG. 1
2. Remove the brush idler plate from the brush base.
Turn the idler plate locking knob counter- clockwise
to remove (Figure 2).
3. Connect the slotted end of the brush to the drive
hub (Figure 3).
4. Connect the idler plate to the brush and reinstall
the idler plate. Make sure the idler plate hooks
engage the brush base and that the locking knob is
secure (Figure 4).
NOTE: If storing the machine for an extended period,
raise the scrub head to the transport position (Fig. 19).
FIG. 2
FIG. 3
FIG. 4