The "Remote On/Off" Function (Ps600-12 Up To Ps800-48 Models Only) - tbs electronics Powersine PS200-12 Manual Del Propietário

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

For best operating results, the inverter should be placed on a flat surface. To ensure a
trouble free operation of the inverter, it must be used in locations that meet the
following requirements :
a. Avoid any contact with water on the inverter. Do not expose the inverter to rain or
moisture.
b. Do not place the unit in direct sunlight or other high temperature environments.
Ambient air temperature should be between 0 C and 50 C (humidity < 95% non
condensing). Note that in some extreme situations the inverter's case temperature can
exceed 70 C.
c. Do not obstruct the airflow around the inverter. Leave at least 10 centimeters
clearance around the inverter. Do not place items on or over the inverter while it's
operating. When the inverter is running to hot, it will shut down until a safe
temperature level is reached to restart the inverter.
d. Never use the inverter at locations where there is gas or explosion danger, like for
example directly on top of batteries.
e. Do not expose the inverter to dusty environments
2.2

The "Remote on/off" function (PS600-12 up to PS800-48 models only)

The Powersine 600-12 up to 800-48 models are equipped with "Remote on/off"
terminals for connection to an external on/off switch. The two wires of the external
switch must be connected to these terminals as indicated below. The slide switch on the
frontpanel must be moved to the right (factory setting is left) when operating the unit by
a remote switch as shown below :
control by local switch
The local on/off switch on the frontpanel always overrides the remote switch. So in order
to use the remote switch, the local on/off switch must be in the 'on' or 'auto standby'
(ASB) position.
control by remote switch
max. 50 meters
7
remote spst
switch