ABSORBED
POWER (W)
300
TABLE 8.1
FIGURE 8.1 SINGLE-PHASE ELECTRICAL CONNECTION DIAGRAM
ATTENTION
Whenever connector or cable repair or replacing is needed, do not plug conductor/connector to any of the
feeding conductors. The grounding conductor - the one with green covering, with or without yellow stripes - is
fi t exclusively for grounding. If there is any doubt in relation to this information, or about whether the product
is adequately grounded, consult a expert electrician (one who is acquainted to electrical installation standard).
Note: The electrical grid shall not present a voltage variation over ± 10%.
Voltage drop caused by the start must not be over 10%.
For your safety, the installation must have a grounding conductor and RD.
The Residual Differential (RD) Switch aim is to protect against electrical shock from direct and indirect contact
with electrifi ed parts.
The Circuit Breaker / Fuse aim is to protect the product from short circuit damage.
8. Wiring diagrams and startup keys (orientation)
The diagram in Figure 8.1 shows how the installation of the power extension, which will be used for equipment
startup, must be done by the client at the Distribution Board.
VOLTAGE
CURRENT
(V)
(A)
127
3
220
1,5
Supply voltage
Ground
Customer's responsability
Plug 2P+T
or harness
FOR HOBBY /HOME PRODUCTS
Incorrect grounding conductor /connector installation may result in electric shock risk.
CONDUCTOR
MAX. DIST. (m)
(mm )
VOLTAGE DROP (2%)
35
1,5
50
DJ
DR
F
N
M 1 ~
33
CIRCUIT BREAKER
DR
(A)
10
25A/30mA
6
Legend (Figure 8.1)
Thermo-magnetic circuit breaker
Residual current circuit breaker
Phase
Neutral
Motor eléctrico monofásico
OUTLET WITH
GROUND
CONNECTION
GROUND PIN
FIGURE 8.2