Menu stage 9: Operating modes
Push button
. "9" is displayed.
Menu Operating mode
value
Normal operation
0
(factory setting)
Normal operation with ventilation
1
position
The ventilation position can be initiated by
pressing the second push button on the
hand transmitter or via the signal 112
internal push button (accessory).
2
Partial opening of side sectional doors
Partial opening of approx. 1m can be
initiated by pressing the second push
button on the hand transmitter or via the
signal 112 internal push button
(accessory).
3
Opening-Closing operation
Open-command can be initiated by pressing
the first button and Close-command can be
initiated by pressing the second push
button on the hand transmitter or via the
signal 112 internal push button
(accessory).
Advice:
The 2nd push button of the transmitter
!
has to be teached-in again after changing the
operation mode 1, 2 and 3.
Operation with singe-lane-control
4
Only in combination with traffic light control
A800. Function with termination of green
light via light barrier.
5
Open-Close
Operation with single-lane-control
Like 4, but without termination of the open
phase.
6
Automatic Closing
An external photocell safety device is
required. Set open phase in menu stage A.
7
Automatic Closing
L
ike 6, but termination of the open phase via
light barrier.
Dear customer,
During production the garage door operator
you have purchased has undergone various
checks by the manufacturer to ensure that it is
of impeccable quality. Should this operator or
parts of it prove to be of no use or limited use
as a result of proven material or manufacturing
defects, we shall rectify this, at our discretion,
through free-of-charge repair or replacement.
We shall not accept any liability for damage as
a result of unsatisfactory fitting and
installation, improper putting into service,
incorrect operation and maintenance,
excessive use and overloading as well as any
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
8
Automatic Closing
like 6, but termination of the open phase
via impulse generator
9
Automatic Closing
like 6, but without early warning phase
Operation mode
Automatic Closing
6, 7, 8 and 9):
A light barrier has to be installed
Menu stage "A": Open phases of the door
Press button
. "A" is displayed. These phases can
only be set using the operation mode Automatic
Closing (6, 7, 8 and 9).
Menu
Open phase
value
(without warning time 10 seconds)
0
0 s
1
10 s
2
30 s
3
60 s
4
90 s
5
120 s
6
150 s
7
180 s
8
210 s
9
240 s

Terms of the Guarantee

alterations or modifications carried out to the
operator and accessory parts by the customer.
The same shall also apply for damage incurred
during transit or as a result of force majeure,
external influences or natural wear as well as
special atmospherical stresses. We cannot
accept any liability following alterations or
modifications of functional parts carried out by
the customer. We must be notified of any
defects immediately in writing; on request the
parts in question are to be made available to
us.
(4, 5,
13d
.
We shall not bear the costs for dismantling
and installation, freight and carriage. If a
complaint is proven to be unjustified, the
customer must bear our costs.
This guarantee is only valid in conjunction
with the signed invoice and commences on
the day of delivery. The manufacturer
guarantees that the product is free of defects.
The warranty is granted for a period of 24
months, in as far as the verification overleaf
has been properly filled out. Otherwise the
warranty shall expire 27 months after the date
of manufacture.
GB
Tabla de contenido
loading

Tabla de contenido