Check the local regulations. Make sure there is power supply available. See section Electrical Requirements.
Recommendations
It's the installer's responsibility to fulfill with the spaces specified
in this manual.
The location of the range should be away from the elements
and over a flat resistant surface.
Don't install your range over a carpet or any flammable
material. If the ground under the range is synthetic, make sure it
withstand at least 95°C without damage.
Keep the areas surrounding the range free from gasoline and
other flammable liquids and vapors.
"THIS APPLIANCE SHOULD NOT BE INSTALLED IN BATHROOMS OR BEDROOMS"
Installation
Remove the adhesive tape and packaging materials.
Identify and separate all the parts of the appliance.
The best location for your new range should be in a place
protected from wind flow and with enough space to open the
door oven.
Location Requirements
Minimum spaces for installation (these spaces should be followed)
14-Sep-2015 11:56:11 EDT | RELEASED
ALL ELECTRICAL WORK MUST BE DONE BY A QUALIFIED ELECTRICIAN.
Risk of injury due to overweight
Use two or more people to move and install your product.
Failure to do so may cause damage to your spine or injured.
In some European factories the letter "W" of the part code mentioned herein will be automatically
Don´t get to close from the flames on the burners, don't use
loose clothing when operating the cooktoop.
Provide the correct maintenance to the appliance.
Use this range for household use only, this is not a commercial
appliance.
If you need to move your range, don't lift or take it from the
handles. Always open the oven door, lift from the upper part of
the cavity and move.
WARNING
Don't install cabinets or other furniture over the range.
If hood will be installed, make sure it is at least 61 cm from the
range.
If the range has accessories that need a power supply, make
sure the installation is close from a wall outlet.
A.
46 min minimum distance to top of the cooktop.
B.
33.0 cm maximum upper cabinet depth.
C.
76.2 cm minimum width for upper cabinet.
D.
61 cm minimum clearance to the top of the cooktop to open the glass
cover.
E.
76.5 cm opening width.
F.
This shadowed area is the recommended area for the electrical junction
box.
G.
This shadowed area is the recommended area for the installation of the
rigid gas line.
H.
5.1 cm minimum clearance required from the range to the cabinet or
any other flammable material.
I.
61.0 cm recommended height for the installation of the rigid gas line.
J.
25.4 cm recommended height for electrical installation.
K.
20.3 cm clearance between the cabinet wall and the area for the
installation of the rigid gas line.
L.
12.7 cm recommended clearance for electrical and rigid gas line
installation.
M.
5.1 cm minimum clearance required between back of range to back
panel.
N.
7.6 cm clearance between the cabinet wall and the area for the
electrical installation.
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")
18
15