Configuration

Condensed programming menu
Enables the rapid configuration of the most frequently-used parameters (SPt, C1, SPH, rH01, d0, d1, d4, F3, A1,
A2, A21 and A22). Press the SET key for 3 seconds to access it.
Extended programming menu
Use the extended programming menu to configure all of the unit's parameters in order to adapt it to installation
requirements. Press the SET key for 6 seconds to access it.
IMPORTANT: If the function of the password has been configured as a keypad block (b10=2), or as
an access block to parameters (b10=1), you will be requested to enter the access code programmed in
PAS when attempting to access either of the two functions. If the entered password is not correct, the
unit will go back to showing the temperature.
IMPORTANT: Certain parameters or menus may not be visible depending on the configuration of the
rest of the parameters.
Temperature regulation and control
Description
SPt
Temperature setting (Set Point)
RE
C0
Probe 1 calibration (Offset)
C1
Probe 1 differential (Hysteresis)
C2
Set Point top locking (it cannot be set above this value)
C3
Set Point bottom locking (it cannot be set below this value)
Type of delay for the protection of the compressor:
C4
0=Minimum time of compressor in OFF
1=Minimum time of compressor in OFF and in ON in each cycle
C5
Protection delay time (Value of the option selected in parameter C4)
COOL relay status with fault in probe 1:
C6
0=OFF; 1=ON; 2=ON-OFF according to prog. C7 and C8
Relay time in ON in the event of probe 1 failure
C7
(If C7=0 and C8¹0, the relay will always be disconnected in OFF)
Relay time in OFF in the event of probe 1 failure
C8
(If C8=0 and C7¹0, the relay will always be connected in ON)
Maximum start time from Pump Down
C19
(Values between 1 and 9 seconds will not be accepted) (0=deactivated)
C20
Maximum time for pump down (0= deactivated)
Probe to be viewed in the upper line of the display 0=All probes (sequential)
C21
1=Probe 1 (Chamber) 2=Probe 2 (Evaporator)
C22
Stop fans and compressor on opening door 0=No 1=Yes
C23
Start-up delay for fans and compressor with door open
C26
Probe 3 calibration (Offset)
3=Probe 3 (According to I30)
19 19
1662H411 Ed.01
Values Min.
Def. Max.
ºC/ºF
-50
9.0
20
ºC/ºF
-5.0
0.0
5.0
ºC/ºF
0.2
2.0
20.0
ºC/ºF
C3
20
20
ºC/ºF
-50
0
C2
0
0
Min.
0
0
120
0
0
Min.
0
10
120
Min.
0
5
120
Sec.
0
0
120
Min.
0
0
15
0
1
0
0
Min.
0
0
999
ºC/ºF
-20.0
0.0
20.0
1
2
3
1