Milwaukee M4910-10 Manual Del Operador página 16

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

 Unplug the paint sprayer.
 Remove the spray tip and nozzle tip guard assembly from
sprayer.
 Soak spray tip(s) and nozzle tip guard in water (for water-
based paints) or Klean Strip
Paint Thinner or Klean Strip
(for oil-based paints or varnish); rinse.
 Fill a bucket (waste container) with water (for water-based
paints) or Klean Strip
®
Thinner or Klean Strip
oil-based paints or varnish).
NOTE: If flushing or cleaning using water for water-based
materials, it may be easier to use a garden hose and the
garden hose attachment (included). Remove filter from
intake tube and attach intake tube to garden hose with
attachment.
 Place intake tube into the bucket of water (for latex
materials) or Klean Strip
Paint Thinner or Klean Strip
(for oil-based materials).
 Place return tube into waste container.
 Turn prime/spray lever to PRIME.
 Turn variable pressure control to PRIME.
 Plug in the paint sprayer.
 Turn on/off switch to ON. The paint sprayer will draw
cleaning fluid up the intake tube through the pump and
out the return tube into the waste container. Allow the
cleaning fluid to run through the system until it runs clear.
 Turn prime/spray lever to SPRAY.
 Unlock pistol-grip sprayer.
 Point sprayer at the interior side of waste container to
flush out the high-pressure fluid hose and pistol-grip
sprayer.
 Leave system running for approximately one minute or
until cleaning fluid runs clear.
 Turn prime/spray lever to PRIME.
Final rinse:
 Pour package of Pump Protector Powder into plastic
bottle provided. Add enough water to fill bottle. Securely
install lid on bottle and shake well to dissolve powder.
 Pour contents of bottle into pail or bucket (not provided)
and add 1 gallon water.
OPERATION
Revolutionary White Formula
®
Safer Green Paint Thinner
®
Revolutionary White Formula Paint
Safer Green Paint Thinner (for
®
Revolutionary White Formula
®
Safer Green Paint Thinner
®
 Place intake tube into bucket. Return tube should remain
in waste bucket.
 Turn variable pressure control to PRIME.
 Turn on/off switch to ON.
 The paint sprayer will draw fluid up the intake tube through
the pump and out the return tube into the waste container.
Allow pump protector fluid to run through the system until
the bucket is empty.
 Unplug the paint sprayer.
 Dispose of fluids in waste bucket in accordance with
federal, state, and local ordinances.
CLEANING THE PAINT SPRAYER WITH
GARDEN HOSE (FOR LATEX MATERIAL
ONLY)
See Figure 16.
 Remove filter from intake tube.
 Attach garden hose adaptor to garden hose.
 Push garden hose adaptor onto the intake tube and
secure with butterfly clamp.
 Turn prime/spray lever to PRIME.
 Turn variable pressure control to PRIME.
 Turn on garden hose.
 Turn on/off to ON.
 Run water through system until clear water runs out of
the return tube.
 Turn prime/spray lever to SPRAY.
 Unlock pistol-grip sprayer.
 With the nozzle tip guard assembly removed, point the
pistol-grip sprayer at the interior side of waste container
to flush out the high-pressure fluid hose and pistol-grip
sprayer.
 Leave the system running until clear water runs out of the
pistol-grip sprayer.
 Turn prime/spray lever to PRIME.
 Turn on/off switch to OFF.
 Unplug the paint sprayer.
 Dispose of dirty water in accordance with federal, state,
and local ordinances.
12 — English
Tabla de contenido
loading

Tabla de contenido