- TORCH IN GOOD CONDITION: Try cut-
ting at a slower pace, the arc may not
have enough time to cut through the
work piece.
- DAMAGED COMPONENTS FOUND: Re-
place any damaged or missing com-
ponents and reassemble carefully.
FAST NOZZLE WEAR OR EXCESSIVE SLAG
FORMATION
These two problems have similar causes and
will often appear simultaneously. The same
diagnostic procedures and remedies apply to
both.
The Amperage setting may be too high; try
cutting at a lowest setting possible for the
metal being cut.
• Problems reduced: Take into account the
thickness and type of metal to be cut before
you start. Thinner materials will typically re-
quire lower amp settings.
• Problems persist at lowest practical setting:
Disconnect the Torch Cables. Disassemble the
torch assembly and inspect all internal compo-
nents.
· TORCH IN GOOD CONDITION: Air supply
pressure may be inadequate:
a. Verify that the compressor is delivering at
least 3.5 CFM @ 80 PSI to the tool.
b. The Regulator on the unit must be set to at
least 60 PSI
· DAMAGED COMPONENTS FOUND: Replace
any damaged or missing components and
reassemble carefully.
E N G L I S H •

TECHNICAL DATA

PHASES
INPUT VOLTAGE
CURRENT INPUT
POWER
FREQUENCY
EFFICIENCY
CUTTING VOLTAGE
CURRENT RANGE
CUTTING CURRENT (60%)
PROTECTION CLASS
WEIGHT
MAX. CUTTING CAPACITY
U ser 's manual
1 ~
220 V ~
29 A
6,4 KVA
60 HZ
ɳ 85%
(86 - 96) V ~
...
(15 - 40) A
40 A
IP21S
7,4 KG (16,3 LB)
Steel 16 mm
Stainless Steel 14 mm
Aluminum 12 mm
Copper 12 mm