KRESS KAC859E Serie Manual Del Usuario página 9

Dispositivo de gestión de alimentación de corriente alterna
debris.
3. Do not spray water onto the electrical components.
STORAGE
1. Turn off the power before storage.
2. Store the AC Power Management Device in a dry and secure place that is inaccessible to children and
other unauthorized people.
3. Store the AC Power Management device within a temperature range between 41
TROUBLESHOOTING
The following table gives problems and actions that you can perform if your machine does not operate
correctly.
WARNING: Switch the machine off and remove the battery prior to any troubleshooting.
Problems
After inserting the AC
plug, the four socket
indicator lights do not
turn on and AC power
management device
cannot be used
After inserting the AC
plug, the four socket
indicator lights turn
on but AC power
management device
cannot be used
After inserting the
AC plug, the channel
indicator light turns
red and AC power
management device
cannot be used.
After inserting the AC
plug, the four channel
indicator lights turn on,
but the operating mode
cannot be switched
TECHNICAL DATA
Volts
Max current
Max output
Number of outlets
Cable length
Degree of protection
Machine weight
Possible Causes
1. No AC input power.
2. Home circuit breaker trips.
3. AC power management device is
damaged.
1. AC input exceeds usage range.
2. AC power management device is
damaged.
Circuit load
1. Mode switch button is damaged.
o
F (5
Corrective Action
1. Check if the power socket is live.
2. Remove all loads from the outlet and
reset the home circuit breaker.
3. Replace the AC power management
device.
1. Change the input power supply.
2. Replace the AC power management
device.
After removing the circuit load, unplug
and then insert the AC power cable.
1. Replace the AC power management
device.
KAC859E KAC859E.X**
220-250V~50Hz
16A
3500W
4
2.5m
IPX4
2.48kg
o
C) and 77
o
F (25
o
C).
9
EN
loading

Este manual también es adecuado para:

Kac859e