EuroLite CLS-41 Manual Del Usuario página 15

Idiomas disponibles

Idiomas disponibles

Please use the original packaging if the device is to be transported. Make sure that you pack the device in
the original state.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
Never remove the serial barcode from the device as this would make the guarantee void.
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like
short-circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamps
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need four 230V/500W R7S 117mm pole burner lamps.
Procedure:
Step 1: Unscrew the fixation-screw of the protective grille.
Step 2: Remove the protective grille.
Step 3: Unscrew the fixation-screws of the colour-filter holder.
Step 4: Remove the colour-filter holder.
Step 5: If replacing a lamp, remove the old lamp from the lamp-socket.
Step 6: Insert the new 230V/500W R7S 117mm pole burner lamp into the lamp-socket.
Step 7: Replace the colour-filter holder and tighten the screws.
Step 8: Replace the protective grille and tighten the screw.
Step 9: For transport, replace the protection-cover and tighten the screw.
DANGER TO LIFE!
Only install the lamps with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened colour-filter holder!
CAUTION!
15/35