5.2.3. Usage indicator light
To activate the light indicating if the lock is in use, enter
*--master code--#--13--#. The green LED will intermittently
illuminate
To deactivate it, enter *--master code--#--14--#
5.3. SUB-MASTER FUNCTIONS
5.3.1. Opening
Enter the 8-digit sub-master code and turn the knob
anticlockwise.
Important: When opening with the sub-master code, the user
code will be deleted.
5.3.2. Setting or changing the sub-master code
Enter *--sub-master code--#--04--#--new 8-digit sub-master
code--#
5.2. SUPER MASTER FUNCTIONS
5.2.1. Opening
Enter the 6-digit super master code and turn the knob
anticlockwise.
Important: When opening with the super master code, the
user code will not be deleted.
6. EMERGENCY OPENING
Remove the protective cover from the knob to access the
lock (we recommend the use of a magnet to remove the lid
more easily), insert the master key and turn it clockwise.
Note: Emergency opening does not erase configured codes.
7. LOCK RESET
If you need to initialise the lock (for example, if you have
forgotten the code) enter
button for 8 seconds
The green light will flash with an alarm beep, and the lock will
return to the factory default settings.
8. CHANGING THE BATTERY
20