NOTE ABOUT EVAPORATIVE COOLERS
Ventilation:
Unlike traditional air conditioners, evaporative coolers require
an open ventilation system, not a closed system. Both a fresh
air source and an exhaust opening are required to provide
correct air flow. Typically, a partially opened window or door in
each room where cooling is desired will create correct airflow
for optimum effectiveness of an evaporative cooler. Alternately,
attic ventilation ducts such as UP-DUX
provide sufficient air movement without requiring open windows.
Water bleed or purge:
Evaporative Coolers require a continuous supply of water
to keep the media saturated for maximum cooling. Water
pumped into the cooler must be removed from the unit to
ensure mineral and bacteria build-up do not occur. This can
occur with a gravity-fed steady bleed off stream or a timed
purge system via a pump. A purge pump kit (MCP44-PPK) is
available for purchase on line at www.championcooler.com or
by calling 800.643.8341 See pages 8 and 9 for more details
on purge pump operation.
BEFORE INSTALLING
WARNING: Do not connect electrical power to the unit
until the installation is completed.
The MasterCool MCP Series cooler can be installed in a
sash-style or a slider-style window.
NOTE: Two people are required for assembly and installation.
Alternatively, this unit is approved for in-wall installations.
REQUIRED CLEARANCES/ SPECIFICATIONS:
In all installations, the following clearances are required:
Width: 22"
Height: 22" PLUS: 4" additional space required above
exterior of cabinet for maintenance.
Weight: 93 lbs operating weight.
Tools & Materials Required:
Drill (power or cordless)
Assorted drill bits (for drilling pilot holes for mounting
hardware)
Adjustable Wrench
Phillips Head Screwdriver
Silicone or all-weather caulk for sealing closeout panels
to window frame
Bubble level ( 3 foot level is preferred)
Spacer material (as required)
Water connection Option 1
Standard water hose
Water connection Option 2
Sill-cock valve
Length of ¼" copper or plastic tubing
can be installed to
®
(Not supplied)
For this cooler to effectively cool
a whole house there must be open
windows or doors in each room
where cooling is desired.
NOTE: Evaporative coolers
NOTE: Evaporative coolers
NOTE: For best results, the open windows/doors
should not be on the windward side on the house.
CAUTION: Water expelled from the cooler must be
routed away from any areas that could do damage to
foundations or other vulnerable areas.
NOTE: Drawings in this manual are for illustrative pur-
poses only and may reflect slight differences
depending on design level and configuration.
4
EXHAUST
EXHAUST
Door or window should
be open 4 to 6 inches
WILL NOT
WILL NOT
work in a Closed Room
work in a Closed Room