PRODUCT INSTALLATION

POWER SUPPLY

Please use the attached power, note that power voltage and frequency are the same as the marked voltage and
frequency of device when connecting power. Every device's power should be connected separately, so that de-
vice can be controlled individually.
CABLE SPEC.
CABLE (EU)
CABLE (US)
Brown
Black
Light Blue
White
Yellow/Green
Yellow/Green

DMX CONNECTION

Connection between laser lights and DMX must use the shied cable of diameter more than 0.5mm. Please use
the attached 3 pin XL plug/socket to connect the DMX output/input interface. The connection between socket
and cable as below (note the plug/socket's 3 pin number and position).
DMX-OUTPUT
XLR mounting-sockets (rear view)
2
When using standard DMX512 control signal, the last device's output interface must be connected to a DMX plug.
This plug is putting a 120 ohm resistance between "canon" plug's 2 pin and 3 pin. Showing as below pic. Sticking
this plug into the last device's signal output interface, it will avoid the interference during the process of signal

RIGGING

Attention! The installation must be carried out by qualified service personal only. Improper installation can re-
sult in serious injuries and /or damage to property. Overhead rigging required extensive experience! Working
load limits should be respected, Certified installation materials should be used, the installed device should be
inspected regularly for safety.
PIN
Live
Neutral
Earth
1 ∙ Shield
2 ∙ Shield (-)
1
3 ∙ Shield (+)
3
INTERNATIONAL
L
N
DMX-INTPUT
XLR mounting-plugs (rear view)
2
1
3
P.19
LEN
FUSE : 100 - 240V~
6.3A
PIN3
PIN2
Tabla de contenido