Vito Agro VIBI550 Manual De Instrucciones página 10

Bomba submergible inox aguas sucias
Idiomas disponibles

Idiomas disponibles

EN
art. no. 1737, or another authorized
safety switch can be used at
additionally safety device.
Furthermore, installation regulations
according VDE 0100 part 072,
have to be observed. Please contact
your electrician.
In Austria, according to OVE B/
EN 60 555 part 1 to 3, pumps
which are used in swimming pools
and garden pools, and equipped
with firm power cable should be
fed via an OVE approved isolating
transformer – rated voltage must
not exceed 230V or 120V.
Always check up the pump (above
all power cable and plug) before
each operation. A damaged pump
must not be used. It is absolutely
necessary to have the pump
checked by your electrician. Cable
quality H05RN-F or H07RN-F.
Take care that the electrical
connections are made within dry
area, protected from flooding.
Protect plug and power cable from
heat, oil and sharp edges.
Check line voltage. Data indicated
on the type plate must match
technical data of the mains supply.
Children under age of 12 are not
allowed to operate the pump. Keep
them away from the connected unit.
Before use, first clear the outlet
line.
Observe the minimum water level.
Observe maximum delivery height.
Have the professional electrician
or your agent replace the damaged
cable.
Please use a protective switch.
OPERATING HINTS
Dry-running operations causes
increased wear and are to be
avoided.
Therefore, the pump must be
immediately switched off when
water fails to flow.
The pump is automatically switched
off on overheating by the built-in
thermal motor protector. After
having cooled down, the motor
10
automatically switches on again.
In order to unplug, pull the plum
shell not the power cable.
The power cable must not be used
for mounting or relocating the
pump. For submerging or lifting/
securing the pump, fix a rope to the
carrying handle.
After having pumped chlorinated
swimming pool water or other
liquids leaving residues, the pump
should be rinsed with clear water.
Sand and other abrasive material in
the liquid cause increased wear and
reduce the pump's output.
Avoid running of the pump for more
than 10min, against closed delivery
side of the pump.
The submersible pump sucks
off down to a residual height is
only reached in case of manual
operation, but not in case of
automatic operation.
The submersible pump is equipped
with an automatic deaerating
device whose function is to remove
probable air licks in the pump. If the
water level drops below the vent
valve, some water flows penetrates
outside through the vent valve. This
is not a defect of your pump, but
serves to deaerate the pump.
If in case of manual operation the
pump has sucked off completely and
water flows again after the pump
operation, the pump isn't deaerated
automatically. Then, the pump has
to be switched off for a short time
and then switched on again.
MAINTENANCE. CARE,
STORAGE
CAUTION: FIRST ALWAYS
UNPLUG THE PUMP BEFORE
WORKING ON IT.
Submersible pumps are virtually
maintenance-free.
In case of contamination inside
the pump, the suction base can be
taken off by unscrewing the 3 cross
recessed head screws.
Thus the turbine space can be
cleaned. For safety reasons a
damaged turbine can only be
exchanged by the service centre.
Caution. Repairs on electrical parts
should only be done by your service
centers.
To protect the pump from frost
damage, store the pump in a dry
place.
TROUBLE SHOOTING
GUIDE
Problem
Probable cause
Remedy
Pump is running but doesn't deliver
Air cannot escape, since pressure
line is closed.
Open pressure line (for example
kinked pressure pipe).
Air locks in the suction base.
Wait for a maximum 60 seconds
until the pump deaerates
automatically over the vent valve.
If necessary, switch off and start it
again.
Turbine clogged.
Clean turbine.
When starting the pump, water
height falls bellw the minimum
water level.
Submerge pump deeper (see
minimum water level)
Pump doesn't start or sudenly stops
during operation
Thermal overload switch has
switched the pump off due to
overheating.
Disconnect plug and clean
turbine. Observe maximum media
temperature of 35ºC.
No power.
Check fuses and electric
connections.
Dirt particles (for example pebbles)
are jammed in the suction base.
Disconnect plug and CLEAN
suction base.
Pump runs but output suddenly
decreases
Suction base is clogged.
Clean suction base.