Electrical connection

Before switching the freezer on for the first time, leave it vertical for at least two hours. Then
connect the appliance's power supply lead to a mains socket with earth contact, installed in
accordance with electrical safety regulations. The rated voltage and frequency are stated on
the nameplate on back of the freezer. The appliance must be connected to the electrical mains
and earthed in compliance with the relevant regulations and requirements.
The appliance is able to withstand short fluctuations in voltage of no more than 15% less or
10% more than the rated voltage stated on the nameplate. If the power supply lead has to be
replaced, this operation must only be carried out by a qualified technician. The socket must be
accessible after the appliance has been placed.

Product Description

1. Door
3. Wire basket
5. Thermostat (0, 1 - 7)
7. Adjustable feet

Before using for the first time

- Remove any exterior and interior packaging materials completely, including the adhesive
strips.
- Before it is connected to the mains, the unit must be thoroughly checked for transport
damage, including its power cord.
- Clean the unit as described in the section Maintenance and cleaning.
- To ensure proper functioning, wait for about two hours before connecting the unit and
switching it on after it has been positioned.
- When the unit is first switched on, a slight 'new' smell may be noticed. However, this will
disappear once the cooling process has begun.
Setting and selecting the freezer operating temperature
Temperature Control
The temperature of the freezer is adjusted by means of the knob assembled on the thermostat
box, position "7" being the coldest temperature. The achieved temperatures can vary
according to the conditions of use of the appliance, such as: place of the appliance, ambient
temperature, and frequency of door opening, extent of filling with food of the freezer. The
position of the thermostat knob will change according to these factors. Normally, for an
ambient temperature of approx. 25°C, the thermostat will be adjusted on an average position.
2. Freezer compartment
4. Compressor Run Indicator (GREEN)
6. Power Indicator (RED)
8. Drain plug