Con capucha flexible sistema papr
Idiomas disponibles
  • ES

Idiomas disponibles

Face seal replacement
The face seal is fastened in using hook and loop to remove/replace
Release the press stud strap that goes over the headgear both sides.
Separate the hook and loop from chin and work up the sides until the face seal is free
To re-fit
Start in the chin ensuring the D ring is in the chin and facing outwards.
Line up the hook and loop all the way around ensuring that he face seal is evenly
spread and that there are no gaps.
Once lined up press the hook and loop together once the face is attached re
fasten the headgear strap
PROBLEM SOLVING
Inspect and dismantle this unit only in a clean environment where no presence of
respiratory hazards is suspected. Always leave the contaminated area to assess any
encountered problem. If the alarm activates during the execution of a task, leave the
contaminated area and remove the TH3P R SL filter with the blower with the power on.
If the alarm deactivates, replace the filter; if not, recharge the unit. Check the air flow
with the Flow-Test-Unit. If the problem continues after the system is recharged, ask for
technical support.
Make sure that the battery unit if fully loaded at the beginning of the shift. The AIRMAX
+® PAPR blower unit is set to sound for 1 second once powered; if the alarm still sounds
after check if the hose or filter are clogged; otherwise the battery needs re-placing or re-
charging. If the problem persists, contact Surewerx USA Inc for support.