12
Enable/ Disable User Codes
Note: When all User Codes are disabled, all electronic functions will be disabled as well.
The door must be locked or unlocked manually with the key. Repeat the programming
steps to enable the User Codes.
1. Remove interior cover.
Press programming
button.
14
Change Auto-Lock Time Delay
1. Remove interior cover.
Press programming
button.
4. Choose and press button for delay.
1 30 seconds
4
5 minutes
5
2 1 minute
10 minutes
3
3 minutes
16
Factory Reset
Note: Lock must be in a unlocked position to factory reset.
1. Remove interior cover.
2. The lock will have a long
PRESS and HOLD
programming button for
15 seconds.
A factory reset will delete all User Codes and change all programming to factory settings. At
this time, the lock can only be locked or unlocked manually with the key.
SmartKey Re-Keying
Re-key the lock to work with your existing kw1 key. See the supplied
SmartKey Re-key instructions for more information.
Note: If Auto-Lock is enabled remove batteries before re-keying your lock.
Powerbolt at a Glance
Exterior
Lock
Button
Number
Buttons
SmartKey
Cylinder
Interior
Battery
Holder
Programming
Button
Interior
Turnpiece
Cover
2. Press number 6.
3. Press the Kwikset logo
button.
2. Press number 8.
3. Press the Kwikset logo
button.
5. Press the Kwikset logo
button.
3. Press programming
beep.
button once more.
System Alerts
Action
Lights
Successful Unlock
Flashes GREEN x2
Successful Lock
Flashes AMBER x2
Low battery
Flashes RED x10
Incorrect User Code
Flashes RED x 3
Exceed 3 incorrect
Flashes RED x15
User Code attempts
Alternate RED/
Stuck/Jammed bolt
WHITE Flash x5
Factory Reset
Flashes GREEN x1
Successful
Factory Reset
Flashes RED x3
Unsuccessful
Programming
Flashes GREEN x1
Successful
Programming
Flashes RED x3
Unsuccessful
13
Enable/ Disable Auto-Lock
1. Remove interior cover.
Press programming
button.
Repeat the programming steps to disable the auto-lock.
15
Door Rehanding
1. Remove interior cover.
Press programming
button.
The latch bolt will extend and retract to learn the orientation of the door.
Note: Perform this process for the lock to learn the locking and unlocking direction of the door.
This feature is used for the lock to learn the orientation of your door (left- or right-handed). If
stuck/jammed bolt error continues to occur after performing this step, please make sure there is
no obstruction from strike or door jamb to prevent the bolt from extending.
17
Add/ Change Programming Code
1. Remove interior cover.
Press programming
button.
4. Enter Programming Code.
Enable/ Disable Programming Code:
Optional: A Programming Code enables you to make programming changes without needing
to access the Programming Button. This is ideal for landlords to program the lock without
access to the interior programming button.
Note: Once Programming Code is enabled, the Programming Button is disabled and can
only be used to factory reset the lock.
One Programming Code between 4 to 8 digits can be saved and cannot be the same as any
User Code and cannot be used as a User Code to unlock the lock.
To program the lock with Programming Code:
Programming
Code
To disable Programming Code:
Programming
Code
Sounds
Troubleshoot
2 beeps
2 beeps
10 beeps
Install fresh new batteries
3 beeps
Check code, and retry
Wait 1 minute, check code,
15 beeps
and retry
5 beeps
Clear jam and try again
1 beep
Retry factory reset steps.
Make sure to press the
3 beeps
Programming Button one
more time within 10 seconds
after the long beep.
1 beep
3 beeps
Review Programming steps
4 / 8
2. Press number 9.
2. Press number 0.
2. Press number 3.
5. Press the Kwikset logo
button.
Follow the programming steps WITHOUT
PRESSING the PROGRAMMING BUTTON
Important Safeguards
5.
If using the Auto-Lock features, make sure you
1.
Read all instructions in their entirety.
have your standard key with you to prevent
2.
Familiarize yourself with all warning
locking yourself out.
and caution statements.
6.
Familiarize yourself with the system alerts.
3.
Remind all family members of safety
precautions.
7.
Replace low batteries immediately.
4.
Always have access to your lock's
8.
Dispose of used batteries according to local
standard key.
laws and regulations.
WARNING:
This Manufacturer advises that no lock can provide complete security by itself. This lock may be defeated by forcible or technical
means, or evaded by entry elsewhere on the property. No lock can substitute for caution, awareness of your environment, and
common sense. Builder's hardware is available in multiple performance grades to suit the application. In order to enhance security
and reduce risk, you should consult a qualified locksmith or other security professional.
CAUTION:
Prevent unauthorized entry. Since anyone with access to the back panel can change the User Codes, you must restrict access to the
back panel and routinely check the User Codes to ensure they have not been altered without your knowledge. The use of a
programming code can help protect your system's settings.
Regulatory Compliance
This product complies with
provide reasonable protection
against harmful interference in
standards established by the
a residential installation. This
following regulatory bodies:
equipment generates, uses, and
Federal Communications
•
can radiate radio frequency
Commission (FCC)
energy and, if not installed and
• Industry Canada
used in accordance with the
instructions, may cause harmful
FCC
interference to radio
communications. However, there
This device's wireless operation is
is no guarantee that interference
safe and complies with RF
will not occur in a particular
Exposure requirements. This device
installation. If this equipment
complies with Part 15 of the FCC
does cause harmful interference to
Rules. Operation is subject to the
radio or television reception, which
following two conditions: ( 1 ) this
can be determined by turning the
device may not cause harmful
equiptment o and on, the user is
interference, and ( 2 ) this device
encouraged to try to correct the
must accept any interference
interference by one or more of the
received, including interference
following measures:
that may cause undesired operation.
• Reorient or relocate the receiving
This equipment has been tested and
found to comply with the limits for
antenna.
a Class B digital device, pursuant to
• Increase the separation between
Part 15 of the FCC Rules.
the equipment and receiver.
These limits are designed to
Copyright © 2024 ASSA ABLOY Americas Residential Inc. All rights reserved
3. Press the Kwikset logo
button.
3. Press the Kwikset logo
button.
3. Press the Kwikset logo
button.
Programming
Code
• Connect the equiptment into an
outlet on a circuit di erent from
that to which the receiver is
connected.
• Consult the dealer or an experienced
radio/TV technician for help.
IMPORTANT! Changes or modi cations
not expressly approved by the
manufacturer could void the user's
authority to operate the equiptment.
Industry Canada
This device complies with Industry
Canada licence-exempt RSS
standard(s). Operation is subject to
the following two conditions: ( 1 ) this
device may not cause interference, and
( 2 ) this device must accept any
interference, including interference that
may cause undesired operation of the
device.