Blooma Lucano AFD1024-IB Manual Del Usuario página 4

Idiomas disponibles

Idiomas disponibles

EN
Safety
Symptom
The light comes on during
the day.
The light comes on for no
apparent reason.
Coverage area of sensor is
poor.
216383_s1_s45-5059340191423_5059340230801-Blooma-A5-IM-V03-Multi.indb 4
216383_s1_s45-5059340191423_5059340230801-Blooma-A5-IM-V03-Multi.indb 4
Possible Cause
Unit is located at shaded area.
LUX knob is set to daylight position
The unit may be installed in a
relatively dark location
The product is wired through a
dimmer or timer
The "SENS" control is set too high
Wind is moving trees and bushes in
the detection zone
Cars in the street are being
detected
Reflective objects (such as
swimming pool) in the coverage
area.
Sunlight is falling onto the lens
Unit is sensing motion in the
detection zone
Choose a suitable location for
installing the product, away from
trees, hot ventilator dusts, street
lighting and traffic, which may
interfere with its operation
Solution
Shine a flashlight onto the sensor.
If the light turns off then the fixture
is mounted in an area that does
not allow enough light to enter the
sensor. Relocate the product
Turn the LUX knob anti-clockwise
to suit desired light setting
During daylight, turn the LUX
control slightly anti-clockwise.
When lamp extinguishes, enter
detection area, if PIR still activates,
adjust LUX further in anti-
clockwise direction and enter the
detection zone again. Repeat the
above procedure until the sensor
does not activate when you enter
the detection area
Do not use a dimmer or timer to
control the product. Replace the
dimmer or timer with a standard
on/off wall switch
Decrease the "SENS" setting
Change detection zone / Relocate
the unit
Change detection zone / Relocate
the unit
Change detection zone / Relocate
the unit
Mount unit in a sheltered place or
change detection zone
Test the motion sensor by covering
up the front curved lens with
cardboard to block the view. If the
light turns off then something in
the detection zone is triggering the
sensor. Relocate the unit or change
the sensitivity (distance) of the
sensor
Relocate the unit
30-09-2021 15:10:49
30-09-2021 15:10:49
04
loading

Este manual también es adecuado para:

Lucano afd1024-iw