Jandy
Infinite WaterColors
®
The Jandy Infinite WaterColors
compatible devices. Never use in conjunction with the WaterColors LED Light Controller, LED Waterfall Colorwheel
Controls, a manual switch, or an automation relay. Use of the Infinite WaterColors
to the Infinite WaterColors
Section 2. Installation
RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH:
Before attempting to install or service, ensure that all power to the circuit supplying power to the system is disconnected
or turned off at the circuit breaker. All wiring must be done in accordance with the National Electrical Code
NFPA70
. In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be followed. All applicable local installation
®
codes and regulations must be followed.
2.1
Mount the Smart Sync LED Adapter
1. Mount the Smart Sync LED Adapter in a NEMA approved weatherproof enclosure using the included
mounting screws, as shown in Figure 2 . Enclosure is not included.
2. Minimum Enclosure Size (Internal): 9" x 3" x 4" (228 mm x 100 mm x 75 mm)
Figure 1. Smart Sync LED Adapter Dimensions
Figure 2. NEMA Approved Weatherproof Enclosure
Smart Sync
LED Adapter | Installation & Operation Manual
™
™
ATTENTION
Smart Sync
should only be used to drive Infinite WaterColors
™
™
Light Controller and AquaLink
™
SAVE THESE INSTRUCTIONS
RS automation to operate.
®
WARNING
5.63"
(143 mm)
2.2
Attach Wiring
2.2.1 Wiring Steps
The Infinite WaterColors
must be powered by the listed low voltage pool/spa
transformer Jandy Infinite WaterColors
Connect the low voltage transformer between pool
control system and Smart Sync LED Adapter.
1. Wire to the Infinite WaterColors
compatible device. Strip the four RGB or five
RGBW wires by at least ¼". (Compatible with both
solid and stranded wire 24–14 AWG.)
Smart Sync
™
Smart Sync
requires connection
™
™
1.51"
(38.40 mm)
CAUTION
Smart Sync LED Adapter
™
Light Controller.
™
Smart Sync
™
ENGLISH
™
(NEC
),
®
®
Page 3