Emerson AVENTICS IO-Link AF2 Instrucciones De Servicio página 12

Sensor de medición de caudal
Ocultar thumbs Ver también para AVENTICS IO-Link AF2:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
AVENTICS specific
Index dec
Name
Format
(hex)
(offset)
438
Display 3 bot-
UInt
(0x1B6)
tom
439
Display history
UInt
(0x1B7)
440
Flow simulation
UInt
(0x1B8)
441
Temperature
UInt
(0x1B9)
simulation
442
Pressure simula-
UInt
(0x1BA)
tion
443
Flow medium
UInt
(0x1BB)
444
Reference condi-
UInt
(0x1BC)
tions for the flow
AVENTICS™ IO-Link AF2 | R412027828-BAL-001-AC | English
Lengt
Ac-
Default value
Value
h
cess
range
8 bits
rw
0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw
0 = mass flow
1 = flow speed
2 = volume
3 = volume flow
4 = mass
5 = energy
6 = temperature
7 = pressure
8 bits
rw
0 = 0%
10 = 10%
20 = 20%
30 = 30%
40 = 40%
50 = 50%
60 = 60%
70 = 70%
80 = 80%
90 = 90%
100 = 100%
255 = simulation off
8 bits
rw
0 = 0%
10 = 10%
20 = 20%
30 = 30%
40 = 40%
50 = 50%
60 = 60%
70 = 70%
80 = 80%
90 = 90%
100 = 100%
255 = simulation off
8 bits
rw
0 = 0%
10 = 10%
20 = 20%
30 = 30%
40 = 40%
50 = 50%
60 = 60%
70 = 70%
80 = 80%
90 = 90%
100 = 100%
255 = simulation off
8 bits
rw
0 = air
1 = nitrogen
2 = carbon dioxide CO2
4 = argon
8 bits
rw
0 = ISO8778
1 = ISO6358
2 = DIN1343
3 = DIN1945-1
4 = ISO1217
5 = ISO2533
6 = customer-specific
AVENTICS specific
Com-
Index dec
Name
ment
(hex)
[unit]
445
Customer-spe-
(0x1BD)
cific reference
pressure
446
Customer-spe-
(0x1BE)
cific reference
temperature
447
Input zero point
(0x1BF)
offset for flow
448
Input low flow
(0x1C0)
cut-off
449
Input smoothing
(0x1C1)
filter for flow
450
Flow measuring
(0x1C2)
mode
453
Input zero point
(0x1C5)
offset for pres-
sure
454
Input smoothing
(0x1C6)
filter for pressure
458
Input smoothing
(0x1CA)
filter for temper-
ature
481
Signal quality 1
(0x1E1)
(sensor robust-
ness)
482
Signal quality 2
(0x1E2)
483
Signal quality 3
(0x1E3)
484
Signal quality 4
(0x1E4)
485
PowerUp
(0x1E5)
counter
486
Sensor power
(0x1E6)
supply
487
Sensor tempera-
(0x1E7)
ture
488
Mass flow statis-
(0x1E8)
tics
1 (0x01)
Minimum
2 (0x02)
Maximum
3 (0x03)
Average value
489
Flow speed sta-
(0x1E9)
tistics
490
Volume flow sta-
(0x1EA)
tistics
491
Temperature
(0x1EB)
statistics
Format
Lengt
Ac-
Default value
(offset)
h
cess
Float
4
rw
-1.0 ... 16.0
bytes
Float
4
rw
-20.0 ... 60.0
bytes
Float
4
rw
-10.0 ... 10.0
bytes
Float
4
rw
0.0 ... 10.0
bytes
UInt
8 bits
rw
0 = off
1 = 100ms
2 = 200ms
5 = 500ms
10 = 1sec
20 = 2sec
50 = 5sec
100 = 10sec
UInt
8 bits
rw
0 = standard
Float
4
rw
-0.5 ... 0.5
bytes
UInt
8 bits
rw
0 = off
1 = 100ms
2 = 200ms
5 = 500ms
10 = 1sec
20 = 2sec
50 = 5sec
100 = 10sec
UInt
8 bits
rw
0 = off
1 = 100ms
2 = 200ms
5 = 500ms
10 = 1sec
20 = 2sec
50 = 5sec
100 = 10sec
UInt
8 bits
ro
0 ... 100
UInt
8 bits
ro
0 ... 100
UInt
8 bits
ro
0 ... 100
UInt
8 bits
ro
0 ... 100
UInt
32 bits ro
Float
4
ro
[V]
bytes
Float
4
ro
(Parameter in 0.1°C) [°C]
bytes
Record
12
ro
bytes
Bit (64)
4
ro
bytes
Bit (32)
4
ro
bytes
Bit (0)
4
ro
bytes
Record
12
ro
See index 488
bytes
Record
12
ro
See index 488
bytes
Record
12
ro
See index 488
bytes
Value
Com-
range
ment
[unit]
[bar]
[%]
[%]
[%]
[%]
12