Technical Data; Battery Replacement; Safety Instructions - Esska DIGIMET E40 Instrucciones De Empleo

Ocultar thumbs Ver también para DIGIMET E40:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Display:
RESET will set the displayed quantity back to 0.00.
TOTAL will display the overall total.

Technical Data:

Flow rate measurement range:
Max. permissible working pressure:
Measurement
accuracy:
Permissible
temperature range:
Viscosity of the pumped fluid:
Size (measurement housing
without accessories):
Weight (measurement housing
without accessories):
Pumped media:
Partial total display (resettable):
Overall total display (not resettable):
Power supply:
Battery life:
Materials:
Housing / cover:
Display panel:
Oval gears:
Shaft, cover screws
Seal:

Battery replacement:

Only use 3V Lithium RC 2032 batteries. Watch the polarity when inserting the battery. Before
changing the battery set the counter to 0.00 with „RESET".
To change the battery, release the 3 side housing screws and remove the meter.
The battery is located on the underside of the display pcb.
If the counting function does not work after changing the battery, the meter will have to be recalibrated.
Do not put flat batteries into household waste. Dispose of used batteries in the proper manner.

Safety Instructions:

Non-compliance with the safety instructions can result in danger both to persons and to the
environment and the equipment. Non-compliance with the safety instructions can lead to the
loss of any claims for damages. The operator of the equipment must ensure that the
contents of the Operating Instructions, particularly the Safety Instructions are known to the
operating personal.
-
Comply with the permissible pressures for the meter.
-
Do not use the meter in EX-protected areas.
-
The meter is calibrated at the factory (preset). Before use however check the right
setting with your system.
Do not point the output gun at people or animals! Danger of injury!!
-
When using accessories not supplied by MATO, there is sometimes the danger of an accident. No
liability can be accepted for accidents or damage caused by components from other sources
-
Defective parts must be replaced with genuine spares without delay.
-
Modification or alteration to the equipment is only permitted after discussion with the manufacturer.
-
The operational safety of the equipment is only guaranteed if used as directed.
-
Maintenance, inspection and repairs must only be carried out by qualified specialist personnel,
who have acquainted themselves with the subject by studying the operating instructions.
2 – 40 l/min.
50 bar
+/- 0.5%
-5°C to +60°C max.
5 – 5000 mPa.s
Ø92 * 115 mm high
0.75 kg
Diesel, fuel oil, hydraulic oils (mineral and glycol based),
engine and transmission oils (other media on request)
from 0.00 to 99999 (5 characters)
from 0.00 to 99999 (5 characters)
1 x 3V Lithium RC 2032 (Ø20x3.2)
Up to around10 years depending on use
Aluminium / PA fibre reinforced
Plastic
PA fibre reinforced
Steel
NBR 75
7
Tabla de contenido