5.2.4- Press button SET. The display shows " 2 ".
5.2.5- Press and hold button DOWN (and if necessary UP or DOWN), until the door
reaches the closed position.
Note: In closed position, the door shouldn't make too much force/pressure
against to floor .
During programming of the limit switch in the closing position, the engine track shall NOT show any
curving (not be bowed) (fig. 4) , it shall be completely straight without any deformation (fig. 3).
If the floor where the sectional door is installed has a slope (inclination between the two edges of the floor
where the bottom rubber seals the door), the difference between the highest and lowest end of the floor
can never be compensated with the motor force, but with the panel cuttedf with the same slope. If the
panel is not cutted, the limit switch programming should be done in the highest position of the floor.
5.2.6- Press button SET. The door will open and close automatically to map the open and
close sensitivity force requirements.
Ensure that the mechanical stop (A) does not move when the door makes this
first automatic opening cycle.
5.2.7- It displays " I I " to show setting is complete. If you see the symbol " 5 " it means
that the setting position was not saved, because the mecanical stop is not in the
correct position. See carefully item 5.2.3, and repeat chapter 5.2.
LIKE IT
Fig 3.
Fig 4.