Indicator SOC indicator
Red light -
blinking
Alerting
Battery over voltage
Battery under voltage
Unit under voltage
VTOP under voltage
VTOP over voltage
Battery over temperature
Battery low temperature
Overcurrent when charging
Overcurrent when discharging 1
Overcurrent when discharging 2
Short when discharging
Short when charging
PCB over temperature
Pre-charge resistor over temperature
Battery under voltage
IUIP parallel signal fault
I_WORK parallel signal fault
Parallelization over time
Parallelization readiness failure
Alerting
Solution
Restart the battery. If it's not fixed, contact
customer service.
Charge the battery. Wait for the voltage to
Restart the battery. If it's not fixed, contact
customer service.
Turn off the battery and wait for 2 hours. If it's not
fixed, contact customer service.
Turn off the battery and wait for the temperature
to recover. Restart the battery. If it's not fixed,
contact customer service.
Restart the battery. If it's not fixed, contact
Turn off the battery, remove and check
equipment, restart. If it's not fixed, contact
Turn off the battery and wait for 2 hours. If it's not
fixed, contact customer service.
Charge the battery. Wait for the voltage to
recover.
Turn off the battery, check the communication
cable. Restart the battery. If it's not fixed, contact
recover.
customer service.
customer service.
customer service.