Tabla De Contenido - Panasonic PAW-TD23B6E5AN Manual De Instalación

Tabla de contenido
CONTENTS
1. Safety instructions ............................................... 3
1.1
General information..................................... 3
1.2 Safety instructions for users ..................... 4
2. Product description............................................. 5
2.1. Product identification.................................. 5
2.2. Intended use.................................................. 5
2.3 CE marking ..................................................... 5
2.4 Technical data ................................................ 5
2.5. ErP data (TDS)................................................. 5
3. Installation instructions .................................... 6
3.2. Included in delivery...................................... 6
3.3. Product dimensions..................................... 6
3.5. Pipe installation ............................................. 8
3.6. Electrical installation .................................. 10
4. Maintenance and draining............................... 12
4.1. Checking the manometer........................ 12
4.2. Checking the safety valve........................ 12
4.4 Draining the product....................................12
5. Spare parts............................................................. 13
5.1. Spare parts list ............................................. 13
6. Warranty conditions ......................................... 14
6.1. Warranty conditions .................................. 14
7. Recycling and handover.................................. 15
7.1 Disposal ............................................................ 15
7.2 Handover to end-user..................................15
2
Dear customer
PAW-TD23B6E5 / PAW-TD23B6E5AN is a high-
grade stainless steel tank-in-tank unit with high
performance and very low heat losses, intended
to supply the household with domestic hot wa-
ter and heating to radiators / underfloor heat-
ing.
The unit is insulated with 50 mm. of 4th gen.
PUR insulation material, reducing heat losses
to a minimum. The 230L domestic hot water
tank with a built-in large heating coil will sup-
ply sufficient hot water for a normal household,
while the 60L buffer tank reduces the number of
start and stop sequences for the air/water heat
pump. This increases the heat pump lifespan,
energy efficiency and provides greater comfort.
The tank-in-tank technology also reduces the
total footprint of the system.
Tabla de contenido
loading

Este manual también es adecuado para:

Paw-td23b6e58034199080341993

Tabla de contenido