LP SAFETY:
1. Do not store a spare LP-gas cylinder under or near this appliance.
2. Never fill the cylinder beyond 80 percent full.
3. If the information in "(1)" and "(2)" is not followed exactly, a fire causing death or serious
injury may occur.
4. Do not use this appliance under overhead combustible surfaces.
MINIMUM CLEARANCES:
• Bottom: Non-Combustible Surface
• Sides: 24 inches
• Top: 72 inches
• For Installation on (or over) non-combustible floors only
All LP cylinders to be used with this appliance must be:
1. Constructed and marked in accordance with the specifications for LP-gas cylinders Standard,
CAN/CSA B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.
2. Provided with a listed overfilling prevention device.
3. Provided with a cylinder connection device compatible with the connection for outdoor
cooking appliances.
4. Only a 20 lb. (9 kg) LP gas cylinder is to be used for this appliance.
5. Approximately 18" (46 cm) high & 12" (30 cm) diameter.
ENCLOSURES FOR SELF-CONTAINED LP GAS SYSTEMS:
An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower
levels of the enclosure. This shall be accompanied by one of the following:
1. One side of the enclosure shall be completely open
2. For an enclosure having four sides, a top, and a bottom:
• At least two ventilation openings (see Part IV, Definitions) shall be provided in the sidewalls of
the enclosure, located within 5 in (217 mm) of the top of the enclosure, equally sized, spaced at a
minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s) shall have a total free area
of not less than 1 in2 per lb(14.2 cm2 per kg) of stored fuel capacity.
• Ventilation opening(s) shall be provided at floor level of the enclosure and shall have total free
area of not less than 1/2 in2 per lb (7.1 cm2 per kg) of stored fuel capacity. If ventilation
openings at floor level area are in the side wall, there shall be at least two openings. The bottom
of the openings shall be 1 in (25.4 mm) or less from the floor level and the upper edge no more
than 5 in (127 mm) above the floor level. The openings shall be equally sized, spaced at a
minimum of 90 degrees (1.57 rad), and unobstructed.
Portable Propane Gas Fire Pit
Max. Input: 40,000 BTU/h
Max Gas Supply Pressure: 2.74 kpa
4