The water heater is equipped with a thermal switch, which cuts off power supply of the heating element upon
water overheating or its absence in the water heater. If the water heater is connected to the mains, but water
is not heated and the indicator doesn't light up, then the thermal switch was switched off or not switched on.
To reset the water heater to the operating condition, it is necessary to:
1. De-energize the water heater, remove the plate of the side/lower cover.
2. Press the button, located at the center of the thermal switch, see Fig.7;
3. If the button is not pressed and there is no clicking, then you should wait until the thermal switch
cools down to the initial temperature.
!
Non-professionals are not allowed to disassemble the thermal switch to reset.
Please contact prefessionals to maintain. Otherwise our company will not take
responsiblity if any quality accident happens because of this.
6. TROUBLESHOOTING
Failures
The heating indicator
light is off.
No water coming out
of the hot water outlet.
The water temperature
is too high.
Water leak.
Parts illustrated in this use and care manual are indicative only, parts provided with the
product may differ with illustrations.This product is intended for household use only.
Specifications are subject to change without notice.
Manual reset button
WARNING
Reasons
Failures of the temperature
controller.
1. The running water supply
is cut off.
2. The hydraulic pressure is
too low.
3. The inlet valve of running
water is not open.
Failures of the temperature
control system.
Seal problem of the joint of
each pipe.
NOTE
8
Treatment
Contact with the professional
personnel for repair.
1. Wait for restoration of
running water supply.
2. Use the heater again
when the hydraulic
pressure is increased.
3. Open the inlet valve of
running water.
Contact with the professional
personnel for repair.
Seal up the joints.
(Fig.7)