INTRODUCTION AND COMPLIANCE STATEMENT

The Model 8145 and 8145NC Fresh Air Ventilators are designed to bring in precisely the right amount of outdoor air into today's efficiently designed
homes . Duct the inlet of the ventilator to an outdoor air intake and duct the discharge to the HVAC system, then simply plug the unit in, set the
amount of needed ventilation and select the desired temperature limits .
When properly installed and set, the Model 8145 and 8145NC Fresh Air Ventilators will meet the mechanical ventilation requirements of:
Energy Star Certified Homes
EPA Indoor airPLUS
2012-2018 International Residential Code (IRC)
2012-2018 International Energy Conservation Code (IECC)
California Energy Commission Title 24
ASHRAE Standard 62 . 2 -2010
ASHRAE Standard 62 . 2 -2013 & 2016

SPECIFICATIONS

TABLE 1 – SPECIFICATIONS
External Static Pressure ("w.c.)
0 . 0
0 . 2
0 . 4
0 . 6
FIGURE 1 – DIMENSIONS (INCHES)
CONTROL NOT INCLUDED
ON MODEL 8145NC

INSTALL ELECTRICAL OUTLET

Install a standard NEMA 5-15 receptacle suitable for the location, near where the ventilator will be installed . The ventilator comes equipped with a
6-foot power cord with a standard 3-prong plug .
2 English
Airflow (CFM)
210
180
150
120
23.41
19.66
13.01
INLET: ROUND COLLAR
OUTLET: OVAL COLLAR
FOR 6" DIAMETER DUCT
FOR 6" DIAMETER DUCT
Efficacy (CFM/watt)
5 . 2
4 . 4
3 . 5
2 . 8
Voltage
120 VAC
1 phase
60 Hz
12.25
13.906
90-2514