Cleaning & Servicing
1
Close both isolation valves, open the
air vent, then open the drain valve and
drain the unit.
3
Remove the core cover with tool
provided.
5
2
Re-insert drain valve, unscrew
locking collar and remove the filter
bowl and core.
4
Remove any sludge or magnetite.
Insert core cover into
port block, ensure fins
are horizontal when
pipe vertical and vertical
when pipe is horizontal.
(Continued Overleaf)