technical data
Enclosure design
LF Transducers
HF Transducers
Class D Amp Continuous Power
DSP
Aiming/Prediction Software
SPL (Continuous/Peak)
Frequency Range (-10 dB)
Frequency Range (-3 dB)
Coverage
Audio Signal Connectors
Input
Output
AC Connectors
Power Supply
Nominal Power Requirements
Current Consumption
Cabinet Construction
Grille
Finish
Rigging Hardware
Dimensions (W×H×D)
Weight
Handles
Accessories
technical drawings
626 mm
10˚ Trapezoidal
2 × 10'' High performance woofers
1 × compresion driver,  1.4" horn throat diameter, 75 mm (3 in) voice coil  
1.2 kW
24bit @ 48kHz AD/DA - 4 selectable presets:
Preset1: 4-6 array elements
Preset2: 6-8 array elements
Preset3: 8-12 array elements
Preset4: 12-16 array elements
EASE FOCUS
127/133 dB SPL
66 - 20000 Hz
88 - 17000 Hz
90˚ Horizontal
XLR
XLR
2 x Neutrik® PowerCON
Universal, regulated switch mode
100 - 240 V 50-60 Hz
1.3 A
15 mm Birch Plywood
1.5 mm perforated weatherised steel with protective foam
Durable IDEA proprietary Aquaforce High Resistance
paint coating process
High-resistance, coated steel integrated 4-point rigging hardware
10 angulation points (0˚-10˚ internal splay angles in 1˚steps)
626 × 278 × 570 mm
37 kg
2 integrated handles
Power module rain cover (RC-EV20,included)
Rigging frame (RF-EVO20)
Rigging frame stack (RF-EVO20-STK)
Transport cart (CRT-EVO20)
570 mm
- 3 -
278 mm
EVO20-M
1 KW Class-D Active Line-Array System
Integrated DSP Preset List
MEDIUM Vertical Coverage [40
-60
o
]
o
Internal Splay Angulation
Preset
Array Elements
Total Angle Sum
[Avg.]
1
4-6
20º to 25º
[6º]
2
6-8
25º to 40º
[5º]
3
8-12
20º to 40º
[3º]
4
12-16
20º to 40º
[2º]
The Integrated DSP Preset settings have been adjusted for
MEDIUM Vertical Coverage configurations.
Refer to User's Manual for MINIMUM [20
o
- 40
] and MAXIMUM [60
º
º
- 80
]
º
Vertical Coverage external DSP Settings.
Power supply: Universal, regulated switch mode
Nominal power requirement: 100-240 V ±10%, 50-60 Hz
Operating voltage: 90 V - 264 V
Suspension of this product should be implemented by qualified
professionals following safe rigging practices and local regulations.
Refer to the owner's manuals for rigging instructions, system
components and suspension hardware intended for this product.