• Electric Connection:
Note! Verify the data label placed inside the appliance:
- If the symbol
appears on the plate, it means that
no earth connection must be made on the appliance,
therefore follow the instructions concerning insulation
class II.
- If the symbol
DOES NOT appear on the plate, follow
the instructions concerning insulation class I.
Insulation class II
- The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The plug must be easily accessible after the instal-
lation of the appliance. If the appliance is equipped
with power cord without plug, a suitably dimensioned
omnipolar switch with 3 mm minimum opening be-
tween contacts must be fitted between the appliance
and the electricity supply in compliance with the load
and current regulations.
- The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral.
Insulation class I
This is a class I, appliance and must therefore be con-
nected to an effiecient earthing system.
- The appliance must be connected to the electricity
supply as follows:
BROWN = L line
BLUE = N neutral
YELLOW/GREEN =
earth.
The neutral wire must be connected to the terminal
with the N symbol while the YELLOW/GREEN, wire
must be connected to the terminal by the earth
symbol
.
When connecting the appliance to the electricity
supply, make sure that the mains socket has an earth
connection. After fitting the ducted cooker hood, make
sure that the electrical plug is in a position where it
can be accessed easily. If the appliance is connected
directly to the electricity supply, an omnipolar switch
with a minimum contact opening of 3 mm must be
placed in between the two; its size must be suitable
for the load required and it must comply with current
legislation.
• The minimum distance between the support surfaces
of the cooking pots on the cooker top and the lowest
part of the cooker hood must be at least 65 cm. If a
connection tube composed of two parts is used, the
upper part must be placed outside the lower part. Do
not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating
fumes from other appliances generated by other
than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease filter(s)
(Fig.6) so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which
has the same diameter as the air exhaust outlet hole.
If a pipe with a smaller diameter is used, the efficiency
of the product may be reduced and its operation may
become noisier.
• Fixing to the wall:
Drill holes A respecting the dimensions indicated
(Fig.1Y). Fix device to wall and align it horizontally with
the cupboards. When the appliance has been adjusted,
definitely fix the hood using the screws A (Fig.1B). For
the various installations use screws and screw anchors
suited to the type of wall (e.g. reinforced concrete,
plasterboard, etc.). If the screws and screw anchors are
provided with the product, check that they are suitable
for the type of wall on which the hood is to be fixed.
• Fixing the decorative telescopic flue:
Arrange the electrical power supply within the dimen-
sions of the decorative flue. If your appliance is to be
installed in the ducting version or in the version with
external motor, prepare the air exhaust opening. Install
the upper decorative flue's support bracket and fix it on
the wall using the screws A (Fig.1A) so it is in axis with
your hood and respecting the distance from the ceiling
shown in (Fig.1X). Connect flange C to air extraction
hole via an air extraction pipe (Fig.1B). Insert upper
decorative flue inside the lower decorative flue and
rest them on top of the frame. Extract the upper flue
up to the bracket and fix it with the screws Z (Fig.1A).
To transform the hood from a ducting version into a
filtering version, ask your dealer for the charcoal filters
and follow the installation instructions.
USE
MECHANICAL PUSH BUTTON (Fig.2A)
A: ON/FF
B: speed 1
C: speed 2
D: speed 3
E: light
F: motor working indicator
ELECTRONIC PUSH BUTTON (Fig.2B)
A: Press to switch on/off the light.
B: Short pression: Motor ON at first speed. Long
pression: Motor OFF.
C: Short pression: Motor at second speed.
D: Short pression: Motor at third speed. Long
pression: intensive speed for 7' (at the end of this time,
the system will return to the speed set previously).
E: Press to set up the timer of 5 minutes. After
5 minutes the cooker hood will be switched off
automatically (motor and lighting). When the timer
is activated the LED flashes. The timer can not be
activated for intensive speed.
CLEAN AIR: to preserve air quality --> push Timer
button for 3'' with hood off. The hood turns on at first
speed for 10' per hour.
Push any button to disable the function.
FILTER SATURATION ALARM: light button LED
flashes every 30h of hood operation: the anti-grease
filter shall be cleaned. To reset the hood when it is off
push light button for 3'' .
On/off button LED flashes every 120h of hood
operation: the anti-odor filter shall be replaced (filter
version). To reset the hood when it is off push light
button for 3'' .
ELECTRONIC PUSH BUTTON (Fig.2C)
A: Press to switch on/off the light.
B:Short pression: Motor ON at first speed. Long
pression: Motor OFF.
C:Short pression: Motor at second speed.
D:Short pression: Motor at third speed.
- 6 -