Style selections SRGF21626X Manual Del Usuario página 20

Idiomas disponibles

Idiomas disponibles

Troubleshooting
PROBLEM OBSERVED
Gas odor
Delayed ignition
Incorrect burner flame
Ignition failure
POSSIBLE CAUSE
Gas leak
Low gas pressure
Clogged or dirty burner
ports
Incorrect gas supply or
pressure
Clogged or dirty burner ports
The gas cylinder
The problem of leak.
The battery is low or dead.
The problem of ignition
pin
The distance between
electrode ignition pins
is improper.
Wrong connection of
pulse line
The top of the shield is
covered by the lava rocks.
CORRECTIVE MEASURES
Check all gas connections.
Check gas supply pressure.
Clean burner parts--see manual
"Cleaning and maintenance" section.
Check gas supply pressure.
Clean burner parts.
Check the gas cylinder is full or not.
Check the regulator & hose is leaking
or not.
Check the battery is installed or not.
Check the power is sufficient or not.
when pressing down the control knob,
check the ignition pin is discharged or not.
If not, using a match or lighter to
ignite the burner at a safe distance from
the fire pit.
Adjust the distance between the ignition
pins to be 3-5mm in case of ignition
failure (if ignition failure issue
happened).
Check the electrode wire, switch wire
on valve body and pulse ignitor are
connected properly.
Electrode wire
Switch wire
The top of the shield should not be
covered by the lava rocks , please remove
the lava rocks before ignition.
Shield
20
L
L
Shield
loading

Este manual también es adecuado para:

4083927