BATTERY PORT LED FUNCTIONS
See Figure 2.
BATTERY PACK
Power On
Without battery pack
Testing
Hot battery pack
Cold battery pack
Error
Error
Deeply discharged
• Try to repeat the conditions a second time by removing and reinstalling the battery pack. If the LED error status repeats a second time,
try charging a different battery.
• If a different battery charges normally, dispose of the pack that received the error (see your battery pack manual for instructions).
• If a different battery also indicates error, the charger should be replaced.
Charging
Fast charging
Charged
Battery full
Low Input/Charging Voltage
Low Input
GENERATOR CONDITION NOTIFICATIONS
See Figure 4.
IF LCD DISPLAYS:
HIGH TEMP or LOW TEMP when the
battery is installed for charging.
See figures 4a - 4b.
HIGH TEMPERATURE SHUTDOWN
or LOW TEMPERATURE SHUTDOWN.
See figures 4c - 4d.
HIGH TEMPERATURE WARNING or
LOW TEMPERATURE WARNING
PRESS RESET. See figures 4e - 4f.
LOW VOLTAGE SHUTDOWN.
See figure 4g.
LOW VOLTAGE WARNING
PRESS RESET.
See figure 4h.
OPERATION
LED
Solid Red
Ready to charge battery pack.
When battery pack reaches cooled temperature, charger begins charge mode.
Flashing Red
When battery pack reaches warmed temperature, charger begins charge mode.
Flashing Red
Battery pack or charger error.
and Green
Flashing Red
Charger conditions battery until normal voltage is reached, then begins charge mode.
Flashing Green
Battery is being charged.
Solid Green
Charging is complete.
Solid Yellow
Batteries do not have sufficient charging power to run the connected loads.
THE CONDITION IS:
The battery you are charging is outside
of the acceptable charging temperature
range.
The power station is outside of the
acceptable operating temperature range.
The power station is nearing the maximum
high or minimum low temperature
acceptable to operate.
The power station's batteries are
discharged.
The power station's batteries do not have
sufficient charge to run the connected
devices.
ACTION
11 — English
TO RESOLVE:
Allow the battery to reach acceptable tem-
perature range. Battery may have to be
removed from the port and reinstalled before
charging will begin.
Move the power station to a cooler or warmer
area as needed and allow the unit to reach
the acceptable temperature range.
After allowing time for the power station to
cool or warm to an acceptable temperature,
press the reset button to continue operation.
Charge the power station. If condition per-
sists, the power station's batteries should
be replaced.
Disconnect some of the devices. If condition
persists, disconnect all devices and recharge
the power station's batteries.